Single cortical positional screw for fixation of fibular head instability.
Ashlee N Buist, Bettina R M Darveshi
Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Washington State University, Pullman, Washington, USA.
Key points
From the paper's conclusion- Key clinical message: This report documents the successful surgical repair of fibular head instability using a single cortical positional screw.
Abstract
Fibular head instability is a rare, isolated injury in veterinary medicine, with no previous case reports in the veterinary literature. The fibular head is secured proximo-distally by the lateral collateral ligament and craniocaudally by the cranial and caudal fibular head ligaments. A 1-year-old, 26-kg, spayed female border collie mix dog was referred for chronic bilateral Salter Harris-II tibial tuberosity avulsion fractures. The dog was non-weight-bearing on the right pelvic limb, with pain and mobility localized to the right fibular head. Preoperative radiographs showed no fibular pathology. Intraoperatively, the cranial and caudal fibular head ligaments were completely torn, whereas the lateral collateral ligament remained intact. Open reduction and stabilization with a cortical positional screw was conducted. At the 8-week follow-up, the dog was sound at a walk, with a mild intermittent "hitch" at a trot. At 7 mo following surgery, the owner reported a return to high-energy activity. Key clinical message: This report documents the successful surgical repair of fibular head instability using a single cortical positional screw.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Alternative Fixation of a Comminuted Fibular Head Avulsion in a Patient With an Ipsilateral Tibial Intramedullary Nail: A Hybrid Construct Case Report.Cureus · 2026
- Traumatic bony avulsion of the lateral collateral ligament of the knee in a pediatric patient.Journal of surgical case reports · 2026
- Internal fixation of a comminuted femoral neck fracture using pins and a conventional plate in a dog with multiple orthopaedic injuriesVeterinary Record Case Reports · 2026
- A "Suture Staple" Knotless Anchor Technique for Fixation of Tibial Tubercle Avulsion Fractures in Pediatric Patients.Arthroscopy techniques · 2026
- Dedicated Tibial Tuberosity Fixation Plates Provide Comparable Stiffness to Pin and Figure-of-eight Wire Constructs in Ex Vivo Stabilization of Laterally Transposed Tibial Crests.Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2026
- Tibiofibular osteotomy for the treatment of Sneppen type V talar body fracture: a case report.BMC surgery · 2026