From the paper's conclusion- Then, the circuit model is implemented into calculation of lightning transient responses in wind turbine grounding systems with attention to the ground potential rise. © 2026 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.
Abstract
The ground potential rise caused by lightning is an important technical index for lightning protection design of wind turbines. A realistic approach is presented in this paper to calculate the ground potential rise in wind turbine grounding systems under lightning stroke. The electrical parameters of the grounding conductors are given by resistance, conductance, capacitance and inductance. The soil ionization due to dissipating lightning current can be taken into account by the effective radius estimated by the critical electric field intensity of soil ionization. According to the electrical parameters, the grounding conductors are replaced by π‐type circuit units and the circuit model is built for transient analysis of the single wind turbine grounding system and interconnecting configurations of multiple wind turbine grounding systems. The calculated results from the circuit model are compared with the measured ones to perform the model verification. Then, the circuit model is implemented into calculation of lightning transient responses in wind turbine grounding systems with attention to the ground potential rise. © 2026 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Full-process evaluation of lightning protection for multi-circuit 10 kV distribution linesJournal of Physics: Conference Series · 2026
- Transient Characteristics Analysis and Resistance Reduction Optimization of Tower Grounding Electrodes Based on Non-Uniform Transmission Line Impedance ModelEnergies · 2026
- Analysis of the Implementation of Effective Grounding in 400 kV Overhead LinesEnergies · 2026
- Equivalent dynamic model for wind deflection of transmission lines under wind-sand loadsJournal of Physics: Conference Series · 2026
- Frequency-Dependent Cable Modeling for Power-Loss and Voltage-Drop Assessment in Wind Farm Collection Networks: A Tehuantepec Case StudyElectricity · 2026
- Lightning Risk Assessment and Improvement of 110 kV Double-Circuit Transmission Lines on Shared TowersEnergies · 2026