Experimental and numerical investigation of double‐embedded blind‐bolted concrete‐filled steel tube connections subjected to cyclic tension load
Abdul Manan, Moiz Tariq, Azam Khan
Key points
From the paper's conclusion- The findings improve the understanding of the tensile behavior of blind‐bolted connections to CFST columns and provide useful information for the design of blind‐bolted composite joints.
Abstract
Concrete‐filled steel tubular (CFST) columns with limited accessibility require the use of blind‐bolted connections in beam‐to‐column joints. This study investigates the tensile behavior of single anchored blind‐bolted connections in the tension zone of a composite truss joint. The literature examines the effects of bolt type, embedment length, and tube size. However, they are limited to an effective embedment length of 60 mm. This study extends the investigation to embedment lengths of 70, 80, and 90 mm. A washer tube is introduced to improve the anchorage mechanism. Pull‐out tests are conducted to evaluate the tensile performance of the connections. The results show that the tensile capacity is strongly influenced by the effective embedment length. A finite element model is developed in ABAQUS to simulate experimental behavior. The numerical results show good agreement with the experimental data. A comparison with published studies further validates the proposed model. The findings improve the understanding of the tensile behavior of blind‐bolted connections to CFST columns and provide useful information for the design of blind‐bolted composite joints.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- STRUCTURAL PERFORMANCE OF STEEL BEAM END CONNECTION ATTACHED TO CONCRETE FILLED TUBULAR COLUMN REINFORCED BY PERFOBOND RIB SHEAR CONNECTORJournal of Structural and Construction Engineering (Transactions of AIJ) · 2026
- Damage-Controlled Column-Tree Moment Connections Using Replaceable Fuse Plates: Experimental and Numerical EvaluationBuildings · 2026
- Seismic Performance of a Novel Prefabricated Concrete-Filled Steel Tubular Column–Steel Beam Joint with Replaceable ComponentsBuildings · 2026
- Cyclic Behavior of T-Stub Connectors with Single-Side Bolts: Experimental and Numerical InvestigationBuildings · 2026
- Design of bolted shear connectors used in cold-formed steel-lightweight concrete (CFS-LWC) systemsEngineering Structures · 2025
- Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beamsScientific Reports · 2026