Damage-Controlled Column-Tree Moment Connections Using Replaceable Fuse Plates: Experimental and Numerical Evaluation
Pablo Matthews, Eduardo Núñez, Juan Carlos Vielma Pérez, Frank Sanhueza, Ramón Mata, Manuel Chávez-Delgado, Guillermo Bustamante, Sebastián Flores
Key points
From the paper's conclusion- The findings provide experimental evidence supporting the feasibility of damage-controlled column-tree moment connections incorporating conventional replaceable cover plates, while highlighting the influence of connection detailing on cyclic performance and post-earthquake reparability.
Abstract
Improving the seismic performance and post-earthquake reparability of steel moment connections requires designs that concentrate inelastic deformation in replaceable components while protecting primary structural members. Column-tree connections, which combine shop-welded beam stubs with field-bolted beam spans, offer a potential solution. However, experimental evidence remains limited for configurations incorporating conventional rectangular fuse plates. This study investigates their cyclic performance through eight full-scale tests conducted according to the AISC seismic loading protocol, complemented by calibrated finite element simulations. The experimental variables included the number of flange bolts, cover plate thickness, and beam stub length. All specimens sustained a drift ratio of 4% and exceeded 80% of the nominal beam plastic moment capacity. The experimental results revealed that the influence of bolt quantity on connection strength and energy dissipation depends on cover plate thickness, while beam stub length also affects the cyclic response. Inelastic deformation was predominantly concentrated in the replaceable cover plates, with no visible fracture or local buckling observed in the primary structural members. Energy dissipation involved frictional sliding during the initial response and localized cover plate yielding at larger drift demands, although the individual contributions of these mechanisms were not quantified separately. The numerical models reproduced the principal deformation mechanisms and overall hysteretic behavior, although discrepancies remained in stiffness and peak strength. The findings provide experimental evidence supporting the feasibility of damage-controlled column-tree moment connections incorporating conventional replaceable cover plates, while highlighting the influence of connection detailing on cyclic performance and post-earthquake reparability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental investigation of seismic performance of reinforced concrete beam‐column joints with hybrid connections combining friction side plates and composite energy‐dissipation boxesStructural Concrete · 2026
- Seismic performance of externally stiffened ring connections between concrete-filled steel tubular columns and reinforced concrete beamsScientific Reports · 2026
- Seismic Performance of a Novel Prefabricated Concrete-Filled Steel Tubular Column–Steel Beam Joint with Replaceable ComponentsBuildings · 2026
- Cyclic Behavior of T-Stub Connectors with Single-Side Bolts: Experimental and Numerical InvestigationBuildings · 2026
- Experimental study on seismic performance of prefabricated reinforced concrete beam–column jointsStructures · 2026
- Moment-resisting timber frames using mechanical fastener and adhesive connections: review and experimental testsCanadian Journal of Civil Engineering · 2026