Development and Validation of a Highly Sensitive Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for Trace‐Level Determination of N‐Nitroso‐Dabigatran Etexilate in Dabigatran Etexilate Mesylate Drug Substance
P. Chandrashekhar Reddy, B. Jainendra Kumar, Rajender Vadija
Key points
From the paper's conclusion- Therefore, a sensitive liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) procedure was developed and validated for determination of N‐nitroso‐dabigatran etexilate in Dabigatran Etexilate Mesylate drug substance.
Abstract
Nitrosamine drug substance‐related impurities have attracted increased regulatory attention because their occurrence at trace concentrations may affect pharmaceutical quality. Dabigatran Etexilate Mesylate contains nitrogen‐containing functional groups that may be susceptible to nitrosation under certain conditions, resulting in the formation of N‐nitroso‐dabigatran etexilate. Therefore, a sensitive liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) procedure was developed and validated for determination of N‐nitroso‐dabigatran etexilate in Dabigatran Etexilate Mesylate drug substance. Chromatographic separation was achieved on a Shim‐pack Scepter C18 column (150 × 4.6 mm, 3.0 µm) using gradient elution with 20 mM ammonium formate buffer (pH ∼5.0) and acetonitrile: water (90:10, v/v) as mobile phases. Quantitative analysis was performed in positive electrospray ionization mode using multiple reaction monitoring with the transition m/z 658.10 → 365.10. The method was evaluated for specificity, linearity, precision (including intermediate precision), accuracy, and sensitivity. A linear response was obtained across the studied concentration range with a correlation coefficient ( r 2 ) of 0.9979. The limit of detection and limit of quantification were established at 0.0173 and 0.0525 ppm, respectively. Accuracy studies demonstrated satisfactory recovery across the evaluated concentration levels, while precision results confirmed reproducible analytical performance. The developed LC‐MS/MS method provides a sensitive approach for the determination of N‐nitroso‐dabigatran etexilate in Dabigatran Etexilate Mesylate drug substance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Rapid and Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for the Quantification of Nitrosamine Impurities in an Anticoagulant Drug: Application to Drug Substance and Pharmaceutical Dosage FormsSeparation Science Plus · 2025
- Development and Validation of a Trace‐Level LC–MS/MS Method for the Determination of N ‐Nitroso Clozapine in Clozapine Drug SubstanceSeparation Science Plus · 2026
- Validated LC-MS/MS method for ultra-trace determination of N-nitroso-desmethyl sumatriptan in sumatriptan succinate injection.Journal of pharmaceutical and biomedical analysis · 2026
- Development and Validation of a Sensitive LC–ESI–MS/MS Method for Trace Determination of Teneligliptin Nitrosamine Drug Substance‐Related ImpuritiesSEPARATION SCIENCE PLUS · 2026
- Trace-level quantification of N-Nitroso diclofenac in diclofenac sodium by LC–MS/MS using an in-source fragmentation based MRM strategyJournal of Liquid Chromatography & Related Technologies · 2026
- Development and Validation of an LC–MS/MS Method for Trace‐Level Nitrosamine Analysis in Mexiletine FormulationsSeparation Science Plus · 2026