Trace-level quantification of N-Nitroso diclofenac in diclofenac sodium by LC–MS/MS using an in-source fragmentation based MRM strategy
Vijay Srinivas Pothula, Balakrishna Reddy Adla, Gana Manjusha Kondepudi, Devesh Kasireddy, Samanvi Palwai
Aurobindo Pharma (United States) · Hackensack Meridian School of Medicine
Key points
From the paper's conclusion- To facilitate selective trace-level quantification, the analytical strategy incorporated in-source fragmentation of the labile N-NO bond generating a chemically stable denitrosated precursor ion at m/z 294.95 (loss of NO, 30 Da).
Abstract
This study describes the development and validation of a liquid chromatography- tandem mass spectrometry (LC-MS/MS) method for quantification of N-Nitroso diclofenac in diclofenac sodium drug substance and tablet dosage forms. Chromatographic separation was achieved on a Phenomenex Kinetex C18 column using gradient elution with 5 mM ammonium formate in water containing 0.1% formic acid and methanol at a flow rate of 0.5 mL/min. Detection was carried out in positive electrospray ionization mode using multiple reaction monitoring (MRM) transitions at m/z 294.95→241.98 (quantifier) and m/z 294.95→213.98 (qualifier). To facilitate selective trace-level quantification, the analytical strategy incorporated in-source fragmentation of the labile N-NO bond generating a chemically stable denitrosated precursor ion at m/z 294.95 (loss of NO, 30 Da). The method demonstrated excellent sensitivity with limits of detection and quantification of 0.125 ng/mL and 0.250 ng/mL, respectively. The calibration curve was linear over the concentration range of 0.249–3.735 ng/mL with a correlation coefficient of 0.99997. The validated LC–MS/MS method is suitable for routine quality control and trace-level determination of N-Nitroso diclofenac in pharmaceutical matrices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Validation of a Highly Sensitive Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for Trace‐Level Determination of N‐Nitroso‐Dabigatran Etexilate in Dabigatran Etexilate Mesylate Drug SubstanceSEPARATION SCIENCE PLUS · 2026
- Development and Validation of a Trace‐Level LC–MS/MS Method for the Determination of N ‐Nitroso Clozapine in Clozapine Drug SubstanceSeparation Science Plus · 2026
- An analytical quality by design-guided method development for the quantification of N-nitroso-fluoxetine to support mitigation strategies for a fluoxetine drug product.Journal of pharmaceutical and biomedical analysis · 2026
- Ultra-Trace Quantitation of N-Nitroso Epinephrine in Epinephrine containing Formulations by LC–ESI–MS/MSInternational Journal of Drug Delivery Technology · 2026
- A Rapid and Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for the Quantification of Nitrosamine Impurities in an Anticoagulant Drug: Application to Drug Substance and Pharmaceutical Dosage FormsSeparation Science Plus · 2025
- Validated LC-MS/MS method for ultra-trace determination of N-nitroso-desmethyl sumatriptan in sumatriptan succinate injection.Journal of pharmaceutical and biomedical analysis · 2026