Development and Validation of a Sensitive LC–ESI–MS/MS Method for Trace Determination of Teneligliptin Nitrosamine Drug Substance‐Related Impurities
Pooja T. Giri, Anuruddha R. Chabukswar
Key points
From the paper's conclusion- Collectively, these results improved the eco‐efficiency and practical viability of the method.
Abstract
Nitrosamine impurities related to the drug substance are potent mutagens and must be controlled below acceptable levels in the finished pharmaceutical products. In this study, a sensitive and relatively sustainable analytical method was developed and validated for the simultaneous determination of N ‐nitroso teneligliptin impurity (NNTI) and N ‐nitroso teneligliptin impurity‐A (NNTI‐A) in teneligliptin (TEN) active pharmaceutical ingredient (API) and formulation. The chromatographic separation of TEN, NNTI, and NNTI‐A was carried out on an Agilent Eclipse Plus C18 column using a gradient elution procedure at a flow rate of 0.7 mL/min, with aqueous solution containing 0.1% formic acid (FA) and acetonitrile containing 0.1% FA being used as mobile phases A and B, respectively. Quantitative determination of NNTI and NNTI‐A was performed using a positive electrospray ionization source and the following multiple reaction monitoring (MRM) transitions: m / z 456.20 → 310.10 (qualifier) and 456.20 → 242.90 (quantifier) for NNTI and m / z 272.10 → 199.90 (quantifier) and 272.10 → 186.10 (qualifier) for NNTI‐A. The proposed method demonstrated good specificity and high sensitivity, achieving limits of detection and quantification of 0.45 and 1.80 ng/mL for NNTI and 0.22 and 1.35 ng/mL for NNTI‐A, respectively. Recoveries for both impurities ranged from 81.42% to 103.39%, confirming method accuracy and falling within the acceptable range (70%–130%). The method demonstrated satisfactory linearity, accuracy, precision, and robustness, supporting its reliable quantitative determination of NNTI and NNTI‐A in TEN API and marketed tablet formulations. In line with Sustainable Development Goal Target 9.4, we evaluated sustainability using established greenness tools, including the Analytical Eco‐Scale (73), the Analytical Greenness (AGREE; 0.66), the Modified Green Analytical Procedure Index (MoGAPI; 72), and the Click Analytical Chemistry Index (72). Collectively, these results improved the eco‐efficiency and practical viability of the method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Simultaneous Liquid Chromatography Triple Quadrupole Mass Spectrometry Method for Quantification of N ‐Nitroso Teneligliptin and N ‐Nitroso‐Boc‐Piperazine in Teneligliptin Tablet FormulationsSeparation Science Plus · 2026
- Liquid Chromatography–Tandem Mass Spectrometry Method Development and Validation for the Quantification of Process‐Related Nitrosamine Impurities in RanolazineSeparation Science Plus · 2026
- Development and Validation of a Trace‐Level LC–MS/MS Method for the Determination of N ‐Nitroso Clozapine in Clozapine Drug SubstanceSeparation Science Plus · 2026
- Validated LC-MS/MS method for ultra-trace determination of N-nitroso-desmethyl sumatriptan in sumatriptan succinate injection.Journal of pharmaceutical and biomedical analysis · 2026
- Development and Validation of a Highly Sensitive Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for Trace‐Level Determination of N‐Nitroso‐Dabigatran Etexilate in Dabigatran Etexilate Mesylate Drug SubstanceSEPARATION SCIENCE PLUS · 2026
- Green Tandem Mass Spectrometry Method for Carcinogenic Nitrosamine Impurity Determination in Oral‐Gonadotropin Releasing Hormone Receptor Antagonist DrugSeparation Science Plus · 2026