From the paper's conclusion
  • The efficiency of the proposed method was evaluated in urine and blood serum samples, and recoveries of more than 91.9% and relative standard deviations less than 5.8% were obtained.

Abstract

In this study, a filter was fabricated by integrating molecularly imprinted polymer technology with carbon dots, and it was utilized for the extraction of atorvastatin. Data analysis was performed using high‐performance liquid chromatography with ultraviolet detection. Furthermore, the structure of the synthesized sorbent was characterized by Fourier transform infrared spectroscopy, field emission‐scanning electron microscopy, x‐ray diffraction, and nitrogen adsorption‐desorption analysis. The optimization of the extraction parameters was carried out using response surface methodology based on the Box–Behnken design. A linear range of 0.2–800 µg/L was obtained for atorvastatin, with a coefficient of determination ( R 2 ) of 0.9985. The limits of detection and quantification were calculated to be 0.09 and 0.30 µg/L, respectively. The efficiency of the proposed method was evaluated in urine and blood serum samples, and recoveries of more than 91.9% and relative standard deviations less than 5.8% were obtained.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fabrication and Application of Carbon Dots‐Integrated Molecularly Imprinted Polymer for the Extraction and Preconcentration of Atorvastatin From Biological Fluids — Science Skim