Analytical and bioanalytical chemistry

Ratiometric molecularly imprinted electrochemical sensing of atorvastatin based on a Co-MOF/MXene interface.

Nian Huang, Haiyan Wu, Dong Cai, Jianlei Wu, Shenghua Zhou, Jean-François Masson, Haifeng Zhou, Wenjuan Zhou,

School of Resources and Environmental Engineering, Jiangsu University of Technology, 1801 Zhongwu Rd., Changzhou, 213001, Jiangsu, China. · The Jiangsu Key Laboratory of Clean Energy Storage and Conversion, School of Chemistry and Chemical Engineering, Jiangsu University of Technology, 1801 Zhongwu Rd., Changzhou, 213001, Jiangsu, China. hywu@jsut.edu.cn.

Key points

From the paper's conclusion
  • A ratiometric molecularly imprinted electrochemical sensor was developed for the determination of atorvastatin (ATV) based on a Co-MOF/MXene functional interface.

Abstract

A ratiometric molecularly imprinted electrochemical sensor was developed for the determination of atorvastatin (ATV) based on a Co-MOF/MXene functional interface. The conductive Co-MOF/MXene composite was employed to construct an electroactive interface, followed by the electropolymerization of polythionine (pThi) and the construction of an o-phenylenediamine (o-PD)-based molecularly imprinted layer. In the resulting sensing system, the [Fe(CN)6]3-/4- response was used for ATV quantification, while the pThi response served as the reference signal for ratiometric analysis. Density functional theory (DFT) calculations further provided molecular-level insight into the interactions between ATV and o-PD, supporting their favorable association during pre-polymerization complex formation. Under optimized conditions, the proposed sensor exhibited a linear response to ATV over the range of 5 to 150 nM with a detection limit of 1.4 nM and a limit of quantification of 4.7 nM. Compared with the non-ratiometric response, the ratiometric strategy showed better repeatability, reproducibility and storage stability. The sensor exhibited satisfactory selectivity and achieved satisfactory recoveries for ATV in spiked environmental water samples, with results consistent with those obtained by ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry. The proposed strategy provides a feasible approach for integrating molecularly imprinted recognition with ratiometric electrochemical signal readout for ATV analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Ratiometric molecularly imprinted electrochemical sensing of atorvastatin based on a Co-MOF/MXene interface — Science Skim