Ratiometric molecularly imprinted electrochemical sensing of atorvastatin based on a Co-MOF/MXene interface.
Nian Huang, Haiyan Wu, Dong Cai, Jianlei Wu, Shenghua Zhou, Jean-François Masson, Haifeng Zhou, Wenjuan Zhou,
School of Resources and Environmental Engineering, Jiangsu University of Technology, 1801 Zhongwu Rd., Changzhou, 213001, Jiangsu, China. · The Jiangsu Key Laboratory of Clean Energy Storage and Conversion, School of Chemistry and Chemical Engineering, Jiangsu University of Technology, 1801 Zhongwu Rd., Changzhou, 213001, Jiangsu, China. hywu@jsut.edu.cn.
Key points
From the paper's conclusion- A ratiometric molecularly imprinted electrochemical sensor was developed for the determination of atorvastatin (ATV) based on a Co-MOF/MXene functional interface.
Abstract
A ratiometric molecularly imprinted electrochemical sensor was developed for the determination of atorvastatin (ATV) based on a Co-MOF/MXene functional interface. The conductive Co-MOF/MXene composite was employed to construct an electroactive interface, followed by the electropolymerization of polythionine (pThi) and the construction of an o-phenylenediamine (o-PD)-based molecularly imprinted layer. In the resulting sensing system, the [Fe(CN)6]3-/4- response was used for ATV quantification, while the pThi response served as the reference signal for ratiometric analysis. Density functional theory (DFT) calculations further provided molecular-level insight into the interactions between ATV and o-PD, supporting their favorable association during pre-polymerization complex formation. Under optimized conditions, the proposed sensor exhibited a linear response to ATV over the range of 5 to 150 nM with a detection limit of 1.4 nM and a limit of quantification of 4.7 nM. Compared with the non-ratiometric response, the ratiometric strategy showed better repeatability, reproducibility and storage stability. The sensor exhibited satisfactory selectivity and achieved satisfactory recoveries for ATV in spiked environmental water samples, with results consistent with those obtained by ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry. The proposed strategy provides a feasible approach for integrating molecularly imprinted recognition with ratiometric electrochemical signal readout for ATV analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fabrication and Application of Carbon Dots‐Integrated Molecularly Imprinted Polymer for the Extraction and Preconcentration of Atorvastatin From Biological FluidsSEPARATION SCIENCE PLUS · 2026
- Covalent and non-covalent synergy in molecularly imprinted polymer-coated hollow nanocages for selective electrochemical recognition of azithromycin.Mikrochimica acta · 2026
- Dy-MOF-based electrochemiluminescence probe regulated by ACQ inhibition and Ti2AlC conductivity for targeted detection of sulfadiazine.Food chemistry · 2026
- A Synergistic Experimental and Computational Approach to the Design of MIPs Targeting Metronidazole.Analytical chemistry · 2026
- Preparation of UiO-67 metal-organic framework carbon paste electrode as a sensor for electroanalytical determination of Ofloxacin in human plasmaResults in Chemistry · 2025
- Dual-sensor potentiometric platform utilizing β-cyclodextrin ionophores and Cu-gallic MOFs for ophthalmic drugs determination in rabbit aqueous humorSensing and Bio-Sensing Research · 2026