Applied Sciences

Study on a Quantitative Detection Method for Tetracycline Using Molecularly Imprinted Polymers

Hanyi Dai, Runting Zhang, Chen Zhao, Keding Yan

Key points

From the paper's conclusion
  • The results showed good linearity for TC over the concentration range of 0–0.35 μmol/L, with a limit of detection of 0.028 μmol/L.

Abstract

To meet the demand for the rapid on-site quantitative detection of tetracycline (TC) residues in food samples, this study developed a portable quantitative detection method based on a molecularly imprinted fluorescent test strip. TC molecularly imprinted polymers were combined with CdTe quantum dots to fabricate test strips with target-recognition and fluorescence-response capabilities, and a portable fluorescence detection system was built as an accessory. To suppress noise and baseline fluctuations in the scanned signals, digital filtering, characteristic peak identification, virtual baseline correction, and peak-area integration were employed to extract the effective signals of the test line (T) and the control line (C), and a TC calibration model was established based on the ratio of the net peak areas of the two lines (T/C). The results showed good linearity for TC over the concentration range of 0–0.35 μmol/L, with a limit of detection of 0.028 μmol/L. Recoveries in spiked milk and honey samples ranged from 97.48% to 103.12%. By integrating molecularly imprinted recognition, quantum dot fluorescence responses, and portable signal analysis, this method offers a potential approach for rapid on-site screening of TC residues in food.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers