Magnetic resonance in medicine

Multi-Echo Versus T2-Prepared pCASL: Methodological Considerations for Measuring Water Transport Across the Blood-Brain Barrier.

Helena Durrant, Matthias J P van Osch, Lena Václavů

C.J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.

Key points

From the paper's conclusion
  • Although multi-echo provides superior SNR, it may underestimate T2 at short PLDs. The underlying cause of this finding remains unresolved; however, preliminary simulations indicate it could result from partial signal crushing of flowing spins by readout gradients. In contrast, the longer readout of the T2-prep approach is more prone to blurring and artifacts. These findings highlight important trade-offs between the two techniques and underscore the need for careful sequence selection in T2-based BBB water exchange studies.

Abstract

PURPOSE: T2-based pCASL measures water transport across the blood-brain barrier (BBB) by separating signal from intravascular and extravascular label based on the distinct T2 relaxation times of blood and tissue. Two commonly used approaches encode T2 information differently: Multi-echo sequences employ a multi-echo turbo spin-echo readout, whereas T2-prepared (T2-prep) sequences apply a preparation module consisting of multiple 180° refocusing pulses prior to a single-echo readout. It remains unclear which approach provides more reliable estimates of BBB water exchange. This study directly compares them in terms of T2 estimation and signal-to-noise ratio (SNR). METHODS: In vivo experiments implemented each method separately, as well as in a single combined sequence, using Hadamard-encoded multi-post-labeling delay (PLDs = 600,1600, 2600 ms) pCASL. Simulations evaluated the effects of T2 decay and label arrival during the readout. RESULTS: T2 estimates were comparable at PLDs of 1600 and 2600 ms. At the shortest PLD of 600 ms, multi-echo yielded lower T2. Multi-echo demonstrated higher temporal and spatial SNR, whereas T2-prep showed increased T2 blurring and image artifacts in the unsubtracted images, consistent with simulations. CONCLUSION: Although multi-echo provides superior SNR, it may underestimate T2 at short PLDs. The underlying cause of this finding remains unresolved; however, preliminary simulations indicate it could result from partial signal crushing of flowing spins by readout gradients. In contrast, the longer readout of the T2-prep approach is more prone to blurring and artifacts. These findings highlight important trade-offs between the two techniques and underscore the need for careful sequence selection in T2-based BBB water exchange studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Multi-Echo Versus T2-Prepared pCASL: Methodological Considerations for Measuring Water Transport Across the Blood-Brain Barrier — Science Skim