arXivPreprintOpen accessphysics.med-ph

Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative Evaluation

Jianing Zhang, Jun Wang, Joseph G. Woods, Shaoyou Ye, Shuai Ming, Hongwei Li, Wei Hu, Wei Wei,

Key points

From the paper's conclusion
  • We developed and validated a vendor-agnostic pseudo-continuous ASL (PCASL) sequence using the open-source Pulseq framework, and assessed its extensibility to advanced perfusion imaging.

Abstract

Purpose: Inter-scanner variability in cerebral blood flow (CBF) quantification limits reproducibility in multi-center arterial spin labeling (ASL) studies. We developed and validated a vendor-agnostic pseudo-continuous ASL (PCASL) sequence using the open-source Pulseq framework, and assessed its extensibility to advanced perfusion imaging. Methods: A vendor-independent PCASL sequence was implemented in Pulseq and deployed on 3T scanners from Siemens, GE, and United Imaging. Seven healthy volunteers underwent single-post-labeling-delay (PLD) PCASL on all platforms, including test-retest scans. An in-house adapted Siemens vendor-based PCASL sequence served as reference. Reproducibility was assessed using within-subject coefficient of variation (CVwithin), root mean square error (RMSE), regional CBF correlation, and voxel-wise variation ratio maps. Multi-PLD PCASL and planning-free VE-PCASL were implemented as proof-of-concept extensions. Results: Mean gray matter (GM) CBF was similar across implementations. Test-retest GM CVwithin was below 4% on all platforms; Siemens-Pulseq had the lowest value (2.65%), versus 3.64% for the native sequence. GM RMSE between Siemens-Vendor and Pulseq implementations was comparable to test-retest RMSE, and all inter-scanner CVwithin values were below 3%. Voxel-wise variation ratio distributions were centered near 100%, suggesting cross-vendor variability comparable to physiological baseline fluctuations. Multi-PLD and VE-PCASL ran successfully on all platforms, yielding consistent CBF/ATT maps and vascular territory delineations. Conclusion: Pulseq-based PCASL enables vendor-agnostic perfusion imaging with low inter-scanner variability. This open-source approach provides a reproducible, standardized solution for multi-center ASL studies and facilitates deployment of advanced ASL techniques in clinical research.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative Evaluation — Science Skim