Temporal evolution acquisition based arterial spin labeling (TEA-ASL) for accurate estimation of apparent T2 of perfusion signal in brain.
Jiawen Sun, Chenhe Yuan, Junqi Xu, Jiekai Zhu, Ning Huang, Ning Wang, Yiling Liu, Qing Wei,
Department of Radiology & Institute for Medical Imaging Technology, Ruijin Hospital,Shanghai Jiao Tong University School of Medicine, Shanghai, China. · Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China.
Key points
From the paper's conclusion- We propose a novel temporal evolution acquisition based ASL (TEA-ASL) sequence incorporating an optimized variable refocusing flip angle (RFA) train to preserve signal across all TEs.
Abstract
Accurate quantification of apparent transverse relaxation (T2) in the brain can be useful for non-invasive assessment of blood oxygenation and blood-brain barrier (BBB) function. While arterial spin labeling (ASL) combined with multi-echo readouts offers a contrast-agent-free approach to map apparent T2, in vivo applications remain challenging due to rapid signal decay and low signal-to-noise ratio (SNR) at longer echo times (TEs), likely leading to overestimation of T2 values. We propose a novel temporal evolution acquisition based ASL (TEA-ASL) sequence incorporating an optimized variable refocusing flip angle (RFA) train to preserve signal across all TEs. Data were acquired on a 5T MRI system combining a pseudo-continuous ASL (pCASL) with the proposed TEA readout with 12 echo times (32-384 ms). The variable RFA scheme significantly improved signal stability across the echo train compared to conventional acquisition with constant RFAs. Accuracy and clinical feasibility of the proposed method was validated by simulations, phantom scans, in-vivo test/retest experiments and in a patient with middle cerebral artery stenosis. The proposed TEA-ASL technique provides robust apparent T2 mapping in the brain at ultra-high field, offering a promising tool for probing oxygenation-related haemodynamics and BBB-associated pathophysiology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Non‐Contrast Assessment of Blood–Brain Barrier Permeability to Water: Improved Signal Modeling and Data AcquisitionMagnetic Resonance in Medicine · 2025
- Enhancing Cerebral Blood Flow Quantification: A Comprehensive Review of Denoising, Artifact Correction, and Simulation in Arterial Spin Labeling MRI.Sensors (Basel, Switzerland) · 2026
- Pseudo-continuous arterial spin labeling (pCASL): a practical clinical guide to contrast-free cerebral perfusion imaging in stroke and steno-occlusive disease.Emergency radiology · 2026
- Recent advances in arterial spin labeling MRI for imaging brain tumors.Magma (New York, N.Y.) · 2026
- Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3TmedRxiv · 2026
- Vendor-Agnostic Pseudocontinuous Arterial Spin Labeling Using Pulseq: Cross-Vendor Quantitative EvaluationarXiv · 2026