Receive-Only Coupled Wireless Radiofrequency Probe for Endocavity MR Imaging Using a pTx System.
Akbar Alipour, Volkan Acikel, Sayim Gokyar, Oktay Algin, Çağdaş Oto, Priti Balchandani, Hilmi Volkan Demir, Ergin Atalar
BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, New York, USA. · Aselsan, REHIS, Ankara, Turkey.
Key points
From the paper's conclusion- A novel interventional approach for localized SNR enhancement in MRI was demonstrated using a wireless RF resonator probe and a dual-drive pTx system. The proposed technique enables local signal enhancement while minimizing transmit-field interactions, thereby facilitating safe interventional MRI and potentially improving image quality and diagnostic performance.
Abstract
PURPOSE: To enhance the SNR in MRI within a localized region of interest using a novel interventional wireless RF resonator probe combined with a dual-drive pTx system. METHODS: A dual-drive body birdcage coil was operated in a linearly-polarized mode to decouple a passive RF resonator probe from the transmit field while maintaining the resonator in a receive-only coupled mode. The resonator was fabricated using standard microfabrication techniques and tuned to the Larmor frequency of a 3T MRI system. The 10-g specific absorption rate (SAR) distribution was simulated to identify potential hot spots around the resonator prior to heating experiments. To evaluate the interaction between the resonator probe and the linearly-polarized transmit field, SNR and flip-angle distributions were measured in a phantom. In vivo imaging studies were subsequently performed using the resonator probe in conjunction with the linearly-polarized dual-drive birdcage coil. RESULTS: Temperature measurements demonstrated a normalized temperature increase of less than 0.10°C, corresponding to a SAR value below 1.2 W/kg. Experimental flip-angle mapping confirmed effective magnetic decoupling of the resonator probe using linearly-polarized dual-drive transmission. An SNR enhancement factor of 1.6 was achieved within the region of interest in phantom experiments. In vivo imaging demonstrated a 2.0 ± 0.2-fold SNR enhancement in the vicinity of the resonator probe. CONCLUSION: A novel interventional approach for localized SNR enhancement in MRI was demonstrated using a wireless RF resonator probe and a dual-drive pTx system. The proposed technique enables local signal enhancement while minimizing transmit-field interactions, thereby facilitating safe interventional MRI and potentially improving image quality and diagnostic performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Augmented 3T imaging performance of the Temporomandibular joint using wireless resonators.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- Optimal Transmission Performance of Quadrature Wireless Resonators at 3 T.Magnetic resonance in medicine · 2026
- Reducing RF-Induced Heating of DBS in 3 T MRI Using Dual-Role Receive Arrays as Wireless Resonators: A Simulation Study.IEEE access : practical innovations, open solutions · 2026
- Multistage preclinical evaluation of a retrievable 3 T MR-resonant inferior vena cava filter and snare loop for MRI-guided interventions.CVIR endovascular · 2026
- Spatially selective RF sensitivity for cortical MRI using the highest-order mode of a head-conformal birdcage-inspired resonator.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- A High-Performance Conformal Metamaterial for 1.5 T Wrist Magnetic Resonance Imaging.ACS applied materials & interfaces · 2026