Stim-CODE: PNS and CNS Constraint Optimized Diffusion-Encoding for Neuroimaging on 200 mT/m Whole-Body Gradients.
Ariel J Hannum, Michael Loecher, Qingping Chen, Eric Arbes, Kawin Setsompop, Maxim Zaitsev, Daniel B Ennis
Department of Radiology, Stanford University, Stanford, California, USA. · Division of Medical Physics, Department of Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Key points
From the paper's conclusion- Stim-CODE maximizes hardware capabilities to achieve time-optimized diffusion-encoding while respecting CNS and PNS, enabling similar diffusion-weighting as conventional approaches with reduced TE and higher SNR.
Abstract
PURPOSE: Ultra-high-performance whole-body MRI gradients ( G max ≥ 200mT/m, S max ≥ 200 T/m/s) can reduce echo times (TE) in diffusion-weighted imaging (DWI), improving SNR. However, full hardware utilization is limited by cardiac (CNS) and peripheral (PNS) nerve stimulation thresholds. This work demonstrates Stimulation Constraint Optimized diffusion-encoding (Stim-CODE) for neuro diffusion. METHODS: Stim-CODE uses the gradient optimization (GrOpt) toolbox to optimally design diffusion-encoding gradient waveforms subject to a CNS or PNS "constraint envelope" based on other gradient events in the sequence. Stim-CODE was evaluated in simulations and in vivo protocols with in-plane resolutions of 1.5 × 1.5 mm 2 and 1.0 × 1.0 mm 2 across G max = [45, 80, 200] mT/m and S max = 200 T/m/s. Healthy volunteers (N = 10) underwent neuro DWI at b = 1000 s/mm 2 with Monopolar, Stim-CODE- M 0 , Bipolar, and Stim-CODE- M 1 encoding. SNR, apparent diffusion coefficient (ADC) maps, and ADC uncertainty were quantified. One volunteer underwent DTI with the same encoding schemes acquired at b = [1000, 3000]s/mm 2 . RESULTS: Stim-CODE reduced TEs across all b -values, with larger gains for higher resolutions, greater G max , and M 1 -nulled waveforms. Phantom and in vivo experiments confirmed equivalent diffusion-weighting with TE savings and SNR improvements. Stim-CODE- M 1 had significant SNR gains over Bipolar scans, but some differences in global ADC were observed. DTI metrics were similar across scans, with Stim-CODE showing lower uncertainty. CONCLUSION: Stim-CODE maximizes hardware capabilities to achieve time-optimized diffusion-encoding while respecting CNS and PNS, enabling similar diffusion-weighting as conventional approaches with reduced TE and higher SNR.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra-High Gradient Scanners.Magnetic resonance in medicine · 2026
- Bilateral Breast Gradient Insert Prototype for Strong Diffusion Encoding at 3 T.Magnetic resonance in medicine · 2026
- Whole-Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses.Magnetic resonance in medicine · 2026
- Optimized Gradient Waveforms for Tensor-Valued Diffusion MRI Under Time-Dependent Diffusion Using Double-Isotropic Matched Encoding (DIME).Magnetic resonance in medicine · 2026
- Dual-phase systolic and diastolic cardiac diffusion tensor imaging using higher order motion compensation spin echo sequences at 300 mT/m gradient strength.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
- Design of a nonlinear double-breast single-axis gradient coil with controlled anterior-posterior gradient variation for diffusion-weighted imaging.Magma (New York, N.Y.) · 2026