Design of a nonlinear double-breast single-axis gradient coil with controlled anterior-posterior gradient variation for diffusion-weighted imaging.
Feng Jia, Gerrit C Arends, Philipp Amrein, Edwin Versteeg, Dennis W J Klomp, Maxim Zaitsev, Chantal M W Tax, Sebastian Littin
Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany. feng.jia@uniklinik-freiburg.de. · Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.
Key points
From the paper's conclusion- This framework enables the development of high-performance, robust local gradient coils, facilitating the clinical implementation of advanced DWI protocols for breast cancer screening.
Abstract
INTRODUCTION: High-performance whole-body gradient systems show promise for breast diffusion-weighted imaging, but their performance is constrained by physiological limits. Although local nonlinear gradient coils can provide stronger gradients while remaining within these limits, they often exhibit a substantial reduction in the gradient amplitude of the z-component of the magnetic field near the chest wall. METHODS: We introduced an optimization framework incorporating a constraint on the anterior-posterior variation in the encoding gradient amplitude. A figure of merit combining coil efficiency and minimum wire width was defined to assess performance. A prototype was constructed to validate the design methodology. RESULTS: The optimized coil achieved a 2.35-fold efficiency increase over standard linear coils. Compared to previous nonlinear designs, the new constraint reduced spatial variation by 35.7% and improved minimum efficiency near the chest wall by 2.6-fold. Experimental field maps matched simulations with errors under 8%. DISCUSSION: The proposed method effectively mitigates the trade-off between gradient strength and spatial uniformity along anterior-posterior direction. By enhancing performance in the posterior breast region, the design addresses a critical limitation of previous local coils. CONCLUSION: This framework enables the development of high-performance, robust local gradient coils, facilitating the clinical implementation of advanced DWI protocols for breast cancer screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bilateral Breast Gradient Insert Prototype for Strong Diffusion Encoding at 3 T.Magnetic resonance in medicine · 2026
- A multi-constraint gradient coil optimization method based on an improved MOEA/D.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- Whole-Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses.Magnetic resonance in medicine · 2026
- Stim-CODE: PNS and CNS Constraint Optimized Diffusion-Encoding for Neuroimaging on 200 mT/m Whole-Body Gradients.Magnetic resonance in medicine · 2026
- Diffusion MRI protocol design for reliable parameter recovery: a unified framework across biophysical modelsarXiv · 2026
- Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra-High Gradient Scanners.Magnetic resonance in medicine · 2026