Vagal Response and Cough Reflex During Atrial Fibrillation Ablation Under Deep Sedation: A Comparison Across Pulsed Field Ablation Systems.
Jumpei Saito, Kenji Kuroki, Takeaki Goto, Chisa Asahina, Koji Sudo, Akira Sato
Department of Cardiovascular Medicine University of Yamanashi Yamanashi Japan.
Key points
From the paper's conclusion- Overall vagal response rates did not differ among FARAPULSE, PULSESELECT, and VARIPULSE (61.4%, 67.5%, and 58.8%, respectively; p = 0.596).
Abstract
BACKGROUND: Pulsed field ablation (PFA) is increasingly used for atrial fibrillation (AF), but device-specific autonomic and respiratory reflex responses remain insufficiently characterized. We aimed to compare vagal responses and cough reflexes among three commercially available PFA systems across individual pulmonary veins and the posterior wall. METHODS: This retrospective single-center study included 200 consecutive patients who underwent AF ablation with FARAPULSE (n = 83), PULSESELECT (n = 83), or VARIPULSE (n = 34). Vagal response was operationally defined as bradyarrhythmia requiring temporary back-up pacing during energy delivery. Cough reflex was assessed intraprocedurally at the left superior pulmonary vein (LSPV), left inferior pulmonary vein (LIPV), right superior pulmonary vein (RSPV), right inferior pulmonary vein (RIPV), and posterior wall. RESULTS: Baseline characteristics were generally similar among groups, although heart failure and diabetes mellitus (DM) differed significantly. Overall vagal response rates did not differ among FARAPULSE, PULSESELECT, and VARIPULSE (61.4%, 67.5%, and 58.8%, respectively; p = 0.596). In contrast, overall cough reflex rates differed significantly (75.9%, 91.6%, and 55.9%; p < 0.001), driven by consistently higher rates with PULSESELECT. On logistic regression, male sex, body mass index, and use of PULSESELECT versus FARAPULSE were independently associated with cough reflex. CONCLUSIONS: Cough reflex was most frequent with PULSESELECT, whereas no significant difference in vagal response was observed among platforms. Recognizing these differences may improve procedural planning, sedation strategy, and prophylactic management during PFA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrophysiology Team-Administered Conscious Sedation for Pulsed-Field Versus Radiofrequency Ablation in Atrial Fibrillation.Anesthesiology research and practice · 2026
- Does posterior wall ablation in conjunction with pulmonary vein isolation improve outcomes in patients with persistent atrial fibrillation undergoing pulsed field ablation?European Heart Journal · 2026
- Procedural characteristics and acute outcomes with different pulsed field ablation systems for atrial fibrillationJournal of Interventional Cardiac Electrophysiology · 2026
- Comparative Clinical and Procedural Outcomes Among Three Pulsed Field Ablation Systems for Atrial Fibrillation: A Prospective Real-World Study.Heart rhythm · 2026
- Contemporary pulsed field ablation systems for atrial fibrillation: a systematic review and network meta-analysisEuropean Heart Journal · 2026
- Long-term efficacy of pulsed-field ablation devices in real-world atrial fibrillation patients: a direct comparison between the Farapulse and the Affera ablation systemsEuropean Heart Journal · 2026