High‐Sensitivity LC–MS/MS Method for Simultaneous Determination of Structurally Related Impurities 2‐Isoniazid, 3‐Isoniazid and Isonicotinamide in Isoniazid Active Pharmaceutical Ingredient
Rajesh Kumar Boggavarapu, Venkateswara Rao Yamarthi, Jithendra Chimakurthy
Vignan's Foundation for Science, Technology & Research
Key points
From the paper's conclusion- A sensitive, selective and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the simultaneous quantification of trace impurities, namely, 2‐isoniazid, 3‐isoniazid and isonicotinamide, in isoniazid active pharmaceutical ingredient (API) at parts‐per‐million (ppm) levels.
Abstract
A sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous quantification of trace impurities, namely, 2-isoniazid, 3-isoniazid and isonicotinamide, in isoniazid active pharmaceutical ingredient (API) at parts-per-million (ppm) levels. Chromatographic separation was achieved within 6 min using a Zorbax SB Aq column maintained at 40°C. The mobile phase consisted of 10 mM ammonium formate buffer (pH 4.0, adjusted with formic acid) and 0.1% (v/v) formic acid in acetonitrile (48:52, v/v), delivered at a flow rate of 1.0 mL/min. The optimized conditions provided efficient separation, reproducible peak responses and stable ionization for all analytes. The method was validated in accordance with ICH Q2 guidelines with respect to specificity, accuracy, precision, linearity, range, detection limit and quantitation limit. The limits of detection and quantification were established at 0.8 and 2.5 ppm, respectively, demonstrating the high sensitivity of the method for trace impurity determination. The validated method was successfully applied to the analysis of isoniazid bulk drug samples and enabled consistent and accurate quantification of the impurities. The developed LC-MS/MS method is rapid, robust and suitable for routine quality control testing and regulatory impurity monitoring of isoniazid API.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel LC–MS/MS Approach for Ultra‐Trace Analysis of Nitroso Drug‐Related Impurities in Valaciclovir HCl: Method Development and ValidationSeparation Science Plus · 2026
- Development and Optimization of a Sensitive LC–MS/MS Method for the Quantification of N‐Nitroso Bisoprolol in Pharmaceutical FormulationsSeparation Science Plus · 2026
- Validated LC-MS/MS method for ultra-trace determination of N-nitroso-desmethyl sumatriptan in sumatriptan succinate injection.Journal of pharmaceutical and biomedical analysis · 2026
- Development of sensitive LC-MS/MS method for the simultaneous quantification of three potential mutagenic impurities in linezolid drug substance.European journal of mass spectrometry (Chichester, England) · 2026
- A Rapid and Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for the Quantification of Nitrosamine Impurities in an Anticoagulant Drug: Application to Drug Substance and Pharmaceutical Dosage FormsSeparation Science Plus · 2025
- Development and Validation of a Highly Sensitive Liquid Chromatography Coupled With Tandem Mass Spectrometry Method for Trace‐Level Determination of N‐Nitroso‐Dabigatran Etexilate in Dabigatran Etexilate Mesylate Drug SubstanceSEPARATION SCIENCE PLUS · 2026