Development of sensitive LC-MS/MS method for the simultaneous quantification of three potential mutagenic impurities in linezolid drug substance.
Naga Hyndavi Pothamsetti, Bala Krishna Kolli, Kishore Ravada
Department of Chemistry, GITAM School of Science, GITAM (Deemed to be University), Visakhapatnam, India.
Key points
From the paper's conclusion- The verified LC-MS/MS method established excellent linearity, precision, accuracy, and sensitivity, confirming its applicability for precise determination of potential trace-level mutagenic impurities in the Linezolid drug material.
Abstract
3-Fluoro-4-morpholinoaniline, Linezolid N-acetylamino impurity, and Linezolid desacetamide descarbonyl phthalimide (R)-isomer are potential genotoxic impurities that can arise during the synthesis of the Linezolid drug substance. A highly sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS/MS) protocol utilizing multiple reaction monitoring was established for concurrent quantification of these potential genotoxic impurities at trace levels. The separation of Linezolid and 3-fluoro-4-morpholinoaniline, Linezolid N-acetylamino impurity and Linezolid desacetamide descarbonyl phthalimide (R)-isomer impurities are achieved with ACE 3 C18-AR (50 mm × 4.6 mm, 3 µm particle size), column using gradient elution program. In the present study, the chromatographic separation was achieved with phase A consisted of 0.01 M ammonium formate in water, while acetonitrile was designated as phase B, both delivered at a constant flow rate of 0.5 mL min-1. The multireaction monitoring transition for 3-fluoro-4-morpholinoaniline, Linezolid N-acetylamino impurity, and Linezolid desacetamide descarbonyl phthalimide (R)-isomer are 197.11>131.08, 239.21>151.24, and 400.15>189.18 monitored at optimized collision energy of -18 eV, -18 eV, and -22 eV, respectively. The developed method confirmed high sensitivity, with values corresponding to the limits of detection and quantification at 0.125 and 0.38 ppm, respectively for 3-fluoro-4-morpholinoaniline, Linezolid N-acetylamino impurity, and Linezolid desacetamide descarbonyl phthalimide (R)-isomer. Accuracy was established through recovery studies, with recovery values ranging from 70% to 130%, in compliance with the predefined acceptance criteria. The verified LC-MS/MS method established excellent linearity, precision, accuracy, and sensitivity, confirming its applicability for precise determination of potential trace-level mutagenic impurities in the Linezolid drug material.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and Validation of a Sensitive LC–ESI–MS/MS Method for Trace Determination of Teneligliptin Nitrosamine Drug Substance‐Related ImpuritiesSEPARATION SCIENCE PLUS · 2026
- Novel Potential Genotoxic Impurity Identification and Quantification by Using Quality by Design Approach in Angiotensin II Receptor BlockerSeparation Science Plus · 2025
- Liquid Chromatography–Tandem Mass Spectrometry Method Development and Validation for the Quantification of Process‐Related Nitrosamine Impurities in RanolazineSeparation Science Plus · 2026
- Sensitive Quantification of N-Nitroso Dibutylamine Impurities in Tramadol Tablets Using Optimized LC-MS/MS Method.Drug metabolism and bioanalysis · 2026
- Development and Optimization of a Sensitive LC–MS/MS Method for the Quantification of N‐Nitroso Bisoprolol in Pharmaceutical FormulationsSeparation Science Plus · 2026
- Eco‐Friendly and Highly Sensitive Liquid Chromatography Mass Spectrometric Method for Trace Level Quantification of N ‐Nitroso Dorzolamide in Dorzolamide Drug Substance and Ophthalmic FormulationsSeparation Science Plus · 2026