Diagnostic Radiographers' Application of the Radiation Protection Principles of Justification, Optimisation and Dose Limits in Mpumalanga Province, South Africa.
Wandile Witness Mkhonza, Shantel Lewis, Nicole Robyn Badriparsad
Medical Imaging and Radiation Sciences, University of Johannesburg, Johannesburg, Gauteng, South Africa.
Key points
From the paper's conclusion- The application of radiation protection principles was inconsistent. Justification was achieved through referral assessment but was compromised by systemic barriers. Optimisation demonstrated suitable room designs but was limited by resource accessibility. Dose limitation was hindered by device usage and feedback despite high issuance.
Abstract
INTRODUCTION: The effective application of radiation protection principles is essential for minimising unnecessary radiation exposure and reducing associated risks to patients, personnel, and the public. This study investigated the application of radiation protection principles by diagnostic radiographers in Mpumalanga province, South Africa. METHODS: The quantitative cross-sectional study employed stratified random sampling and an online questionnaire to collect data from diagnostic radiographers working in Mpumalanga hospitals. The data were analysed using descriptive and inferential statistics. RESULTS: The survey achieved a response rate of 85.6% (n = 125, N = 146). Most participants (38.4%, n = 48) had 0-5 years of work experience. Referral forms often lacked sufficient clinical history (64.8%, n = 81), with diagnostic radiographers frequently supplementing by assessing the body region of concern (49.2%, n = 60). Lack of communication between radiologists and diagnostic radiographers was noted when referrals were incomplete (31.3%, n = 36) or when requested examinations did not correspond with the clinical history (32.8%, n = 38). Most participants (66.4%, n = 81) felt undervalued due to hierarchical structures. Most X-ray rooms had functional warning lights (80%, n = 84). Full lead shields (98.1%, n = 102) were widely accessible, and lead goggles (33.7%, n = 34) were the least accessible. Although most participants were issued with personal radiation monitoring devices (97.1%, n = 99), only 53.5% (n = 53) reported consistent use, and 33.3% (n = 32) received radiation dose readings. CONCLUSION: The application of radiation protection principles was inconsistent. Justification was achieved through referral assessment but was compromised by systemic barriers. Optimisation demonstrated suitable room designs but was limited by resource accessibility. Dose limitation was hindered by device usage and feedback despite high issuance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Occupational radiation protection in interventional radiology: A multicenter multimethod study of anesthesiology personnel.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Comparative Analysis of Radiation Protection Measures Used in Both Government and Private Radio-diagnostics Facilities in Port Harcourt MetropolisIconic Research and Engineering Journals · 2026
- Radiation Safety Knowledge, Perceptions, and Self-Reported Practices Among Healthcare Workers in Radiology and Nuclear Medicine: A Cross-Sectional Survey.Healthcare (Basel, Switzerland) · 2026
- Knowledge, Practices, and Training Needs Related to Radiation Protection among Critical Care Staff Exposed to Portable Radiography: A Cross-Sectional Study.Health physics · 2026
- Knowledge, Compliance, and Associated Factors of Radiation Protection Adherence Among Dental Students, Interns, and Dentists: A Cross-Sectional Study.European journal of dentistry · 2026
- Occupational radiation dose surveillance and radiation-protection compliance in podiatric surgery facilities: A nationwide cross-sectional study in Spain.Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2026