Determining Body Surface Area Using Long‐Axial Field‐of‐View Total‐Body PET: A Novel Method Without Additional Radiation Exposure
Chun‐Lei Han, Wen‐Shan Huang, Jie‐Qun Yu, Na‐Wa Xie, Jie‐Hua Xu
Key points
From the paper's conclusion- We developed a method to determine BSA and morphological parameters, including total body volume, from routine long‐axial field‐of‐view (LAFOV) total‐body PET (TBPET) data without additional imaging or radiation exposure.
Abstract
Background Body surface area (BSA) is used to normalize physiological measures and guide chemotherapy dosing and is traditionally estimated using height‐ and weight‐based formulas. Although whole‐body computed tomography has been investigated for direct BSA estimation, BSA determination from total‐body positron emission tomography (PET) has not been reported. We developed a method to determine BSA and morphological parameters, including total body volume, from routine long‐axial field‐of‐view (LAFOV) total‐body PET (TBPET) data without additional imaging or radiation exposure. Methods Software was developed in C# using the open‐source Insight Segmentation and Registration Toolkit and Visualization Toolkit, with SimpleITK and ActiViz wrappers ( https://simpleitk.org/ , https://www.kitware.eu/activiz/ ). SimpleITK was used for DICOM import and body‐mask segmentation, vtkMarchingCubes for surface reconstruction, and vtkMassProperties for BSA calculation. Technical validation was performed using a routine quality‐control phantom. Clinical data from 20 patients were acquired using a uEXPLORER LAFOV TBPET scanner. Results PET‐derived BSA differed from the physically measured phantom surface area by 0.19%. In patients, PET‐derived BSA was strongly correlated with BSA estimated using the DuBois, Mosteller, and Haycock formulas ( r = 0.962, 0.973, and 0.974, respectively). Maximum percentage differences were 6.58%, −5.84%, and −8.34%, respectively. Conclusions BSA can be determined from routine LAFOV TBPET data without additional radiation exposure, with potential applicability to multibed whole‐body PET. PET‐derived BSA correlated strongly with conventional estimates, although individual differences exceeded 8%. Larger studies using appropriate reference methods are needed to establish accuracy and clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolboxEuropean Journal of Nuclear Medicine and Molecular Imaging · 2026
- Physiologically Based Pharmacokinetic (PBPK) Modeling of FIX in Pediatric Hemophilia B: Extravascular Distribution and Dosing Optimization.Pharmaceutics · 2026
- Estimation of the effective dose in torso 18F-fluorodeoxyglucose PET/CT: an analysis of real-world clinical data from 51,784 patient scansEJNMMI Physics · 2026
- Comparative dosimetry study of PARaDIM and RT-PHITS with ICRP publication 128: calculation of organ doses from 18F-FDG radiopharmaceutical.Radiological physics and technology · 2026
- Simulation of low-dose PET imaging protocols for assessment of pancreatic beta-cell mass in pediatric type 1 diabetesmedRxiv · 2026
- Automated patient-derived noise power spectrum estimation in abdominal CT: a preliminary validationBiomedical Physics & Engineering Express · 2026