From the paper's conclusion- This study evaluates organ doses from ¹⁸F-FDG whole-body PET-CT using the phantom-based software PARaDIM and patient image-based software RT-PHITS and compares with reference data from ICRP Publication 128.
Abstract
This study evaluates organ doses from ¹⁸F-FDG whole-body PET-CT using the phantom-based software PARaDIM and patient image-based software RT-PHITS and compares with reference data from ICRP Publication 128. Absorbed dose coefficients (mGy/MBq) were calculated using ICRP Publication 145 mesh-type phantoms in PARaDIM and 20 patient datasets (10 male, 10 female) from 'The Cancer Imaging Archives' website in RT-PHITS. Organs were segmented in 3D Slicer, and dose coefficients were derived after physical decay correction of the resultant dose rates (mGy/s). The patient cohort (n = 20; 10 males, 10 females) had an average age of 52.1 years, height of 172.1 cm, weight of 76.65 kg, and total administered activity of 306.55 MBq. Absorbed dose coefficients from PARaDIM and RT-PHITS ranged from 0.01 to 0.07 mGy/MBq. RT-PHITS showed acceptable agreement with ICRP 128 and PARaDIM for most organs, except for the urinary bladder and heart wall. Standard deviations (SD) for RT-PHITS urinary bladder doses were 0.04 relative to ICRP 128 and 0.12 relative to PARaDIM; heart wall SDs were 0.016 and 0.014, respectively. Overall, RT-PHITS organ doses yielded an average SD of 0.0073, with the highest deviation in the heart wall. The results indicate that anatomical differences lead to measurable variations between the generalized and individualized dosimetry methodologies. Because a consistent physical decay model of 18F was used, these variations primarily reflect structural and geometric factors. This study provides a framework for advancing individualized dosimetry approaches and supports future developments in cumulative exposure assessments and potential theranostic applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimization of patient dose and image quality for positron emission tomography-computed tomography.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Radiation interaction parameters of 18F-FDG: effective atomic number and electron density for PET applicationsEJNMMI Physics · 2026
- Estimation of the effective dose in torso 18F-fluorodeoxyglucose PET/CT: an analysis of real-world clinical data from 51,784 patient scansEJNMMI Physics · 2026
- Dosimetry Data Infrastructure for Individualized Radiopharmaceutical Therapy: International Experience and a Proposed Framework for China.Pharmaceuticals (Basel, Switzerland) · 2026
- MIRD Pamphlet No. 34, Part 1: MIRDctA Customizable Software Tool for CT DosimetryJournal of Nuclear Medicine · 2026
- Dosimetry-Driven Personalization of Radiopharmaceutical Therapies: Evidence and Opportunities.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026