Observer-Related Versus Cross-Modality Variability in Ventricular Quantification by Cardiac CT and Cardiovascular Magnetic Resonance.
Răzvan-Andrei Licu, Alexandra-Mihaela Țolescu-Dobra, Gheorghe-Marian Rotariu, Kincső-Zsófia Lőrincz, Claudia-Raluca Mariean, Marian Pop, Dragoș Constantin Cucoranu, Liviu Moraru,
Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 540142 Targu Mures, Romania. · Department of Radiology, George Emil Palade University of Medicine, Pharmacy, Science and Technology of Târgu Mureș, 540142 Targu Mures, Romania.
Key points
From the paper's conclusion- We compared cross-modality disagreement with intra-modality interobserver variability.
Abstract
Background/Objectives: Ventricular measurements from cardiac computed tomography (CCT) and cardiovascular magnetic resonance (CMR) may differ due to modality-specific, physiological, or observer-dependent reasons. We compared cross-modality disagreement with intra-modality interobserver variability. Methods: Fifty-four patients with CCT and CMR examinations within 36 months were retrospectively analyzed. Left ventricular (LV) end-diastolic volume (EDV), right ventricular (RV) EDV, and LV mass were measured on the same platform; 18 underwent independent second-observer measurements. The primary metric was the standard deviation of paired differences [SD(D)], with bootstrap 95% confidence intervals (CIs). Results: In the repeat-measurement subset, cross-modality SDs were 29.78 mL, 29.19 mL, and 16.72 g for LV EDV, RV EDV, and LV mass, versus 4.83, 7.33, and 6.71 within CCT and 3.57, 3.58, and 4.11 within CMR. Cross-modality variability was 6.16, 3.98, and 2.49 times the CCT and 8.34, 8.15, and 4.07 times the CMR interobserver variability; all 95% CIs exceeded 1. Examination-interval restriction did not materially reduce dispersion, and body-surface-area indexation changed scale but not relative disagreement. Conclusions: Under routine clinical conditions, cross-modality variability in EDV and LV mass exceeded interobserver variability by 2.5- to 8.3-fold. CCT-CMR differences are unlikely to reflect observer-related post-processing variability alone, and consistent modality selection appears preferable to interchanging quantitative thresholds.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Opportunistic volume assessment of left ventricular volume from coronary CT angiography: agreement with cardiac MRIEuropean Heart Journal · 2026
- Cardiovascular magnetic resonance reference ranges and centile-based categories for atrial and ventricular cardiac structure and function: 2026 Update from the Healthy Hearts ConsortiummedRxiv · 2026
- Multimodal Comparison of Left Ventricular Function and Volume Assessment Methods in Patients With Coronary Artery Disease: Echocardiography, Nuclear Myocardial Perfusion Imaging, and Cardiac Magnetic ResonanceiRADIOLOGY · 2026
- Large Language Models in Cardiovascular Imaging: Current Applications and Future ProspectsMed Research · 2025
- CineMR: Tool-Integrated Vision-Language Reasoning for Quantitative Cardiac MRI AssessmentarXiv · 2026
- Routine Chest CTA Reliably Quantifies Left Ventricular Myocardial Mass.medRxiv : the preprint server for health sciences · 2026