Seismic Retrofitting of Nonlinear Masonry Buildings With Newly‐Added Inerter‐Based Elevators via Stochastic Optimization
Jia‐Lin Chen, Meng Wang, Fei‐Fei Sun, Mi Zhao, Satish Nagarajaiah, Xiu‐Li Du
Key points
From the paper's conclusion- Finally, stochastic response analysis and nonlinear time history analysis are conducted, demonstrating that the inerter‐based elevator with a mass ratio of can effectively mitigate the responses of nonlinear masonry structures.
Abstract
In China, many existing residential buildings requiring elevator installation are masonry structures with insufficient seismic performance. To address the dual demand for elevator installation and seismic retrofitting, this study investigates an inerter‐based elevator system for mitigating the seismic responses of nonlinear masonry structures. First, the selected macro‐model (BWBN model) is validated against masonry wall tests to reproduce the hysteretic behavior of both reinforced and unreinforced masonry structures. A statistics‐based method is then employed to derive the backbone curves and calibrate the corresponding BWBN parameters. Subsequently, an analog two‐degree‐of‐freedom system is developed to represent a masonry building equipped with an inerter‐based elevator. Nonstationary ground motions are simulated using the Clough‐Penzien model, and the system responses are obtained through stochastic equivalent linearization in state‐space form. Based on the equivalent linearized earthquake‐structure‐elevator system, an optimization procedure is established to determine the tuning frequency ratio and damping ratio by minimizing displacement, acceleration, and structural energy dissipation indices. Finally, stochastic response analysis and nonlinear time history analysis are conducted, demonstrating that the inerter‐based elevator with a mass ratio of can effectively mitigate the responses of nonlinear masonry structures. Under 200 recorded ground motions, the average displacement reduction ranges from approximately 13.8% to 19.1% for the reinforced masonry structure, depending on the adopted optimization objective.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Innovative Multi-Site Assessment of Sustainable Integrated Seismic and Energy Retrofit Solutions for Mediterranean BuildingsSustainability · 2026
- Seismic performance assessment of inerter-based damping systems for structural vibration control – a comprehensive reviewFrontiers in Built Environment · 2026
- Advancing seismic isolation efficiency of rolling rod base isolators using nonlinear inertial amplifiersNonlinear Dynamics · 2025
- Optimization and Performance Evaluation of Tuned Mass Clutched Inerter for Structural SystemsEarthquake Engineering & Structural Dynamics · 2026
- Earthquake-Resistant Structural Design and Retrofitting Technologies: A Systematic Review of Performance Materials and Resilience OutcomesBuildings · 2026
- Cyclic tensile behavior and component‐based modeling of box connections in prefabricated concrete elevator shafts for retrofitting old dwellingsStructural Concrete · 2026