Key points
From the paper's conclusion- Across various excitations, the NIARRI achieves peak isolator displacement reductions of 84.8%, confirming its effectiveness in enhancing both performance and reliability of seismic isolation systems.
Abstract
Abstract Nonlinear inertial amplifier rolling rod isolators (NIARRI) are introduced in this paper to overcome the existing drawbacks of the conventional base isolators. The Euler-Lagrange equation is employed to derive the governing equations of motion. $$H_{2}$$ H 2 and $$H_{\infty }$$ H ∞ optimisation techniques are employed to derive the closed-form expressions for optimal frequency and damping ratio of the NIARRI. An analysis of the eigenvalues and the eigenvectors demonstrates that the inertial amplifier has two competing design priorities depending on the chosen optimisation case. The $$H_2$$ H 2 case demands that the angle of the inertial amplifier be minimised while the $$H_\infty $$ H ∞ demands that the angle be maximised instead. The transfer matrix formation and harmonic balance method are employed to obtain frequency domain responses, while the Newmark-beta method is employed to obtain time domain responses. According to the frequency domain analysis, the dynamic response reduction capacity of NIARRI is 43.68% superior to conventional BI, while time domain analysis shows 25.21% superior vibration reduction than conventional BI. In addition to reducing structural vibrations, the NIARRI system significantly limits isolator displacements, thereby lowering stroke demands. Across various excitations, the NIARRI achieves peak isolator displacement reductions of 84.8%, confirming its effectiveness in enhancing both performance and reliability of seismic isolation systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of an Inerter-Based Dynamic Vibration Absorber with Adjustable Inertance for Tower Structures: Theoretical Models, Experimental Validations, and Structural Behavior InsightsJournal of Structural Engineering · 2026
- Advanced Stiffened Amplifier Friction Sliding IsolatorsJournal of structural design and construction practice. · 2026
- Nonstationary Stochastic Seismic Optimization of Base‐Isolated Nuclear Power Plant Equipped With Negative Stiffness Amplifying Damper Considering Dynamic Soil–Structure‐InteractionEarthquake Engineering & Structural Dynamics · 2026
- Seismic performance assessment of inerter-based damping systems for structural vibration control – a comprehensive reviewFrontiers in Built Environment · 2026
- Targeted Dual‐Objective Optimization of an Inerter Isolation System for Concurrent Displacement and Acceleration MitigationThe Structural Design of Tall and Special Buildings · 2026
- Design Strategy of Nonlinear Energy Sink Inerter for Vortex-Induced Vibration Mitigation of Long-Span BridgesJournal of Structural Engineering · 2026