New Analytical Possibilities of Ion‐Selective Electrodes in Self‐Powered Bipolar Electrode Arrangement
Ewa Jaworska, Agata Michalska, Roberto Paolesse, Krzysztof Maksymiuk
Key points
From the paper's conclusion- On the other hand, implementation of ISEs into bipolar electrode systems, working in self‐powered mode, opens new attractive analytical possibilities which are proposed and described in the present work.
Abstract
All‐solid‐state potentiometric ion‐selective electrodes (ISEs) with plastic membranes are attractive analytical tools; however, their analytical parameters cannot be easily tuned by instrumental control. On the other hand, implementation of ISEs into bipolar electrode systems, working in self‐powered mode, opens new attractive analytical possibilities which are proposed and described in the present work. One of the tested options are bipolar electrode systems composed of connected cation‐ and anion‐selective electrodes. This setup results in a linear dependence of the current flowing across the bipolar system on the logarithm of electrolyte concentration. The signal magnitude, the slope of the calibration plot, and the detection limit can be modified by the change of the membrane thickness or its composition. An important advantage of this approach is that the reference electrode is not required. Additionally, by appropriately tailoring the composition of the bipolar electrode system, an analytically beneficial linear dependence of the current directly on ion concentration in a selected range can be achieved, including the physiological range of potassium ionsare concentration. In another application mode, as shown experimentally and confirmed by model calculations, bypassing a potentiometric sensor by another ISE can be effectively used for detection limit lowering of the sensor.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Programmable Closed Bipolar Electrochemical Platforms with Ion-Selective Electrode for Electrochemiluminescence Sensing.Analytical chemistry · 2026
- Single-Channel Electrophysiology Using a Miniaturized Montal-Mueller Planar Lipid Bilayer System for Recording a Synthetic K2P Channel.Journal of visualized experiments : JoVE · 2026
- Ion-selective electrodes for in vivo applications in animal models: from single-time measurement to long-term monitoring.Science bulletin · 2026
- Tunable Ion-Sensing Using Coulometric-Based Protocols with Permselective NanomembranesAnalytical Chemistry · 2026
- When Two Interfaces Meet: A Unified Theory for Thin-Membrane Voltammetric Ion Selective Electrodes.Analytical chemistry · 2026
- Pulseometry: A differential readout to compensate signal drift of potentiometric probes.Science advances · 2026