Tunable Ion-Sensing Using Coulometric-Based Protocols with Permselective Nanomembranes
Nuria Martínez-Lorca, Y. Liu, Gregorio Laucirica, Gastón A. Crespo, María Cuartero
Universidad Católica de Murcia · KTH Royal Institute of Technology
Key points
From the paper's conclusion- We found two distinct response ranges: 3–20 μM in the cathodic protocol and 200–1000 nM in the anodic one.
Abstract
High Resolution Image Download MS PowerPoint Slide Herein, we investigate all-solid-state ion-selective electrodes (ISEs) based on permselective nanomembranes (thickness ∼230 nm) in a coulometric mode. The detection of the potassium ion (K + ) has been selected as proof of concept, implementing two electrochemical protocols based on the anodic and cathodic readouts of the same ISE. The electrode consists of an ITO glass substrate with the conducting polymer poly(3-octylthiophene) (POT) electrodeposited on it and a potassium-selective nanomembrane spin-coated over the POT layer. The K + transfer at the membrane-sample interface is mediated by the redox activity of POT, which is in excess with respect to the dopant in the membrane (i.e., the anion part of the cation exchanger, R – ). In the cathodic protocol, the entry of the K + into the membrane is promoted by the POT + reduction to POT 0; while in the anodic interrogation, first, K + enters the membrane with a previous accumulation step, and then it is expelled during the oxidation of the POT 0 to POT + . Both protocols were studied under linear sweep voltammetry and chronoamperometry, followed by signal integration to obtain the charge corresponding to K + . It is demonstrated that this charge is directly proportional to the K + concentration in the bulk solution. We found two distinct response ranges: 3–20 μM in the cathodic protocol and 200–1000 nM in the anodic one. In addition, the cathodic coulometry strategy revealed excellent repeatability and reversibility within the linear range of response. The developed analytical approach demonstrates suitability in the quantification of real samples, i.e., human urine, horse serum, canal water, and standard KCl solution, while providing a linear and tunable coulometric response over a broad concentration range from the nanomolar to the micromolar level. Moreover, the sensor can be readily integrated into microfluidic devices, additionally offering the advantage of small sample volume requirements. The demonstrated reversibility, along with the ability to customize the ionophore in the membrane for an analysis of different ions, renders the proposed concept adaptable and exceptionally suitable for clinical analysis and environmental monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thin-Layer Sample-Ion-Selective Nanomembrane Architecture for Coulometric Cation Sensing.Analytical chemistry · 2026
- Selective Monovalent Cation Transport in Two-Dimensional Polymer Membranes via Charge Control of Nanochannels.Small (Weinheim an der Bergstrasse, Germany) · 2026
- When Two Interfaces Meet: A Unified Theory for Thin-Membrane Voltammetric Ion Selective Electrodes.Analytical chemistry · 2026
- Controlling sub-nanometer pore-entrance size enables kinetic separation of Li+, Na+, and K+ in capacitive deionizationCarbon Trends · 2026
- Biomimetic hydrophobic gating in MXene polypyrrole–based artificial Ion channels for efficient perchlorate sensingNature Communications · 2026
- Threshold-Voltage Ion Sieving in Ultrathin Polymeric Membranes for Energy-Efficient Lithium Extraction.Advanced materials (Deerfield Beach, Fla.) · 2026