Reducing Patient Radiation Skin Dose in Percutaneous Coronary Intervention Using a Dedicated Protocol: A Single-Center Experience.
Muhammad Ghallab, Derek Pineda, Shiv Bagga, Zhongjie Zhang, Gennaro Giustino, Samantha Santori, Jacob Kamen, Bradley Delman,
Creighton University School of Medicine, Omaha, Nebraska, USA. · Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Key points
From the paper's conclusion- Implementation of an SRDL protocol was associated with significant reductions in patient radiation exposure during PCI without increasing procedure time, supporting its use as a safety intervention in high-volume catheterization laboratories.
Abstract
BACKGROUND: Percutaneous coronary interventions (PCI) expose patients and operators to ionizing radiation, posing risks of deterministic effects such as skin injury and stochastic effects including malignancy. Although real-time dosimetry and dose alerts have been associated with radiation-dose reductions in prior reports, the level of patient radiation reduction associated with implementing a formal, multifaceted radiation reduction program has not previously been reported in a high-volume catheterization laboratory. OBJECTIVES: To evaluate the impact of a substantial radiation dose level (SRDL) protocol on patient radiation exposure during PCI. METHODS: This retrospective study analyzed 19,249 PCI procedures at a tertiary center from July 2012 to December 2021. Patients were stratified into a pre-protocol cohort (Phase 1: 17,332 procedures) and a post-protocol cohort (Phase 2: 1917 procedures following implementation in November 2019). The SRDL protocol included real-time radiation monitoring, alert thresholds at 5 Gy air kerma, and structured follow-up for high-dose cases. Study outcomes included air kerma (Ka,r) dose-area product (DAP), contrast volume, and fluoroscopy time. RESULTS: The study cohort (mean age 66.3 years; 28.5% female) demonstrated significant reductions in radiation exposure after implementing the protocol. Median air kerma declined from 2.6 to 2.0 Gy (23% reduction; p < 0.0001), and median DAP decreased from 158 to 125 Gy·cm2 (20.8% reduction; p < 0.0001). Contrast volume was reduced by 15 mL (11.1% reduction; p < 0.0001), while fluoroscopy time remained unchanged (18.1 vs. 18.3 min; p = 0.094). Despite increased procedural complexity in Phase 2 (multivessel PCI: 69.5% vs. 65.2%; p < 0.001), radiation reduction remained significant. CONCLUSIONS: Implementation of an SRDL protocol was associated with significant reductions in patient radiation exposure during PCI without increasing procedure time, supporting its use as a safety intervention in high-volume catheterization laboratories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Operator radiation exposure between left distal and right conventional radial access in patients undergoing PCIEuropean Heart Journal · 2026
- Real-time Radiation Exposure Monitoring in the Cardiac Catheterization Laboratory Using a Digital RRPD Dosimeter.Health physics · 2026
- Evolution of diagnostic reference levels in paediatric cardiac interventional procedures: a narrative review.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Radiation burden in chronic total occlusion percutaneous coronary intervention is driven more by lesion complexity and planned strategy than by the target vessel.Coronary artery disease · 2026
- Impact of Radiation-Attenuating Drape on Exposure in a Contemporary Cardiac Catheterization Laboratory: The ATTENUATE Trial.Journal of the Society for Cardiovascular Angiography & Interventions · 2026
- Ultra-Low-Dose Noise-Free Technology to Reduce Radiation Exposure During Coronary AngiographyCirculation Cardiovascular Interventions · 2026