Characterization of animal tissues for Monte Carlo simulations in ion beam therapy.
Liu Xiaoli, Michael F Moyers
Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Shanghai, China.
Key points
From the paper's conclusion- RLSP measurements were independent of beam energy and ion species. The main determinants of accurate CTN to RLSP conversion are the PDs and fractional hydrogen content of the tissues. The accuracy of PD and EC for input into Monte Carlo transport calculations can be improved by combining DEI and scaled CTN.
Abstract
PURPOSE: To obtain better elemental compositions (ECs), physical densities (PDs), and relative linear stopping powers (RLSPs) of tissues scanned by single or dual energy computed tomography for use by Monte Carlo (MC) simulations of light ion beam therapy. METHODS AND MATERIALS: The RLSPs of 12 animal tissue samples were measured using several different energy proton and carbon ion beams. The EC of each sample was analyzed using the following modern laboratory techniques: Inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), organic elemental analysis (OEA), and ion chromatography (IC). RLSPs were calculated from both measured ECs and literature ECs and then compared with measured RLSPs. All samples underwent single-energy CT (SECT) and dual-energy CT (DECT) scanning after which a dual-energy index (DEI) was derived. A mapping from computed tomography number (CTN) and DEI to PD was performed. RESULTS: For each tissue sample, the measured RLSPs showed no significant dependence on beam energy or ion species, with all values agreeing to within ± 1% except for lung (within ± 2%). RLSPs directly measured and those calculated using measured PDs and ECs agreed within ± 2% except for lung. Measured RLSPs were slightly closer to values from laboratory-determined ECs than to literature ECs. CONCLUSIONS: RLSP measurements were independent of beam energy and ion species. The main determinants of accurate CTN to RLSP conversion are the PDs and fractional hydrogen content of the tissues. The accuracy of PD and EC for input into Monte Carlo transport calculations can be improved by combining DEI and scaled CTN.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Spectral CT in Modern Radiotherapy: A Clinical Framework for Precision Treatment Planning, Adaptive Radiotherapy, and Response Assessment.Clinical oncology (Royal College of Radiologists (Great Britain)) · 2026
- Impact of dual-layer spectral CT-derived stopping power ratio on single-energy CT-based carbon-ion treatment planning for thoracic cancer.PloS one · 2026
- Comparison of proton, helium-ion, and carbon-ion CT imaging for hadron radiotherapy using Monte Carlo simulations.Physics in medicine and biology · 2026
- Generalized multi-energy model for computing radiation treatment parameters on image domain and automated model-selection framework.World journal of radiology · 2026
- Proton treatment-plan dose verification with a DPM-based Monte Carlo engine.Frontiers in oncology · 2026
- Three-dimensional computational evaluation of water-to-air mass stopping power ratio for therapeutic helium-, carbon-, oxygen-, and neon-ion beams and its application to patient-specific quality assurance.Physics in medicine and biology · 2026