Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion Autoencoders
Johannes B. Thalhammer, Kacper Og\'orek, Tina Dorosti, Sebastian Peterhansl, Daniel Frey, Zijin Huang, Theresa Hiu, Tobias Lasser,
Key points
From the paper's conclusion- These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.
Abstract
Large, well-annotated datasets are essential for developing medical artificial intelligence models, yet data sharing is often restricted by privacy regulations. Synthetic images may help address this limitation if they preserve diagnostic information while reducing the risk of reproducing patient data. We developed a diffusion autoencoder-based framework for class-conditional synthetic chest CT generation that incorporates latent-space distance filtering to reduce the likelihood of regenerating training samples. A diffusion autoencoder was trained on the public RSNA 2020 Pulmonary Embolism (PE) dataset. PE-positive and PE-negative images were synthesized by sampling latent representations from class-specific kernel density estimates. Samples with a nearest-neighbor latent-space distance below a predefined threshold were rejected. To assess diagnostic utility, ResNet-50 classifiers were trained across 10 independent runs using real, synthetic, or mixed real-synthetic datasets. Performance was evaluated on a held-out real test set using the area under the receiver operating characteristic curve (AUC), with DeLong 95% confidence intervals (CIs). Models trained on synthetic data achieved an AUC of 0.862 (95% CI, 0.851-0.874), only slightly lower than models trained on real data (AUC = 0.872, 95% CI, 0.861-0.883) and mixed real-synthetic data (AUC = 0.865, 95% CI, 0.855-0.876). These differences were statistically significant (p < 0.05) but small in absolute terms. A nearest-neighbor copy-detection analysis of 38,000 synthetic slices found no direct copies of real training images. These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Harmonizing Fidelity, Utility, and Privacy in Medical Data Synthesis: A Dual Approach via Survival-Aware CVAE and XAI-Guided DDPM.Journal of imaging informatics in medicine · 2026
- Multi-Conditional Diffusion Framework with Texture Constraints for Clinically-Reliable Lesion Synthesis in Virtual Imaging Trials.IEEE transactions on medical imaging · 2026
- Synthetic data augmentation for CT-based emphysema subtype classification: A comparative evaluation of generative and classical approaches.PloS one · 2026
- Image-Conditioned Diffusion Preserves Latent PhysiologicalSignals and Enables Cross-Site Transfer of Synthetic MedicalImagesbioRxiv · 2026
- Review of generative AI for synthetic data generation: a healthcare perspectiveArtificial Intelligence Review · 2025
- The Synthetic Fidelity-Stability Framework (SFSF): A Systematic Multi-Dimensional Benchmark of Synthetic Clinical Laboratory Data GeneratorsbioRxiv · 2026