Journal of imaging informatics in medicine

Harmonizing Fidelity, Utility, and Privacy in Medical Data Synthesis: A Dual Approach via Survival-Aware CVAE and XAI-Guided DDPM.

Mehmet Karaköse, Turan Göktuǧ Altundoǧan, M Mücahit Enes Yurtsever, Süleyman Eken

Computer Engineering, Fırat University, 23119, Elazıǧ, Turkey. · Computer Engineering, Manisa Celal Bayar University, 45140, Manisa, Turkey.

Computational

Key points

From the paper's conclusion
  • Across three seeds, the XAI-guided DDPM reached 98.1 ± 0.1% independent class consistency on chest X-ray and 86.1 ± 2.9% on COVID-CT; however, on COVID-CT its TSTR F1-score (0.639 ± 0.019) was lower than that of the unguided DDPM baseline (0.776 ± 0.017), indicating that the benefit of XAI guidance is contingent upon imaging modality and sample size.

Abstract

Strict data privacy regulations severely constrain the sharing and secondary use of clinical datasets in biomedical research. Generative artificial intelligence offers a viable solution by synthesizing realistic medical data devoid of original patient identifiers and augmenting existing cohorts. This study introduces two distinct modality-specific generative pipelines tailored for medical tabular synthesis and class-aware medical image generation that share a common design principle-the clinically decisive variable (event status or diagnostic class) is an explicit, controlled condition of the generator-and are assessed with a common fidelity-utility-privacy protocol. For tabular synthesis, a Conditional Variational Autoencoder (CVAE) was trained and benchmarked on the METABRIC, GBSG2, and WHAS500 datasets. Experimental results demonstrate that the conditional architecture effectively mitigates the event-collapse phenomenon prevalent in conventional VAE frameworks. For class-conditional medical image synthesis, an explainable AI (XAI)-guided Denoising Diffusion Probabilistic Model (DDPM) was developed and trained on chest X-ray and CT modalities using a stepwise strategy incorporating low-frequency, edge, and density-based anatomical regularizers. The stepwise XAI guidance coupled with anatomy-preserving constraints increased independent class consistency, whereas its effect on downstream classification was modality-dependent. Across five random seeds and six dataset-regime conditions, the CVAE achieved a mean SDV-style quality score of 0.931 ± 0.001 and a Train on Synthetic, Test on Real (TSTR) C-index of 0.739 ± 0.004, with no exact record matches and a mean distance-based membership-inference AUC of 0.555 ± 0.009, i.e., modestly above the 0.5 chance level. Across three seeds, the XAI-guided DDPM reached 98.1 ± 0.1% independent class consistency on chest X-ray and 86.1 ± 2.9% on COVID-CT; however, on COVID-CT its TSTR F1-score (0.639 ± 0.019) was lower than that of the unguided DDPM baseline (0.776 ± 0.017), indicating that the benefit of XAI guidance is contingent upon imaging modality and sample size. Rather than claiming universal superiority, the study contributes explicit event control with a characterized fidelity-privacy trade-off for survival tables and a systematic component analysis of when XAI guidance helps and when it harms image synthesis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers