Susceptibility source separation via Closed-form Alternating Newton-type Optimization
Ignacio Contreras-Z\'u\~niga, Cristian Tejos, Carlos Milovic
Key points
From the paper's conclusion- We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup.
Abstract
Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved accuracy and robustness against artifacts in high-susceptibility regions. Finally, an echo-time analysis of the three-pool model shows that source separation is driven by second-order nonlinearities in signal decay and phase evolution rather than first-order bulk estimates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- PI-uMSS: Prior information-based unsupervised magnetic source separation in quantitative susceptibility mappingNeuroImage · 2025
- A physics-constrained Bayesian framework for QSM with uncertainty quantification and variational susceptibility source separation.Physics in medicine and biology · 2026
- Magnetic susceptibility source separation technology: a narrative review of principles, validation, and clinical translationFrontiers in Neuroscience · 2026
- Rapid whole-brain susceptibility source separation using sub-minute three-dimensional multiple overlapping-echo detachment acquisition.Physics in medicine and biology · 2026
- Separation of Diamagnetic and Paramagnetic Susceptibility Sources in Liver Using DECOMPOSE‐QSMNMR in Biomedicine · 2026
- MORSE-PI: flexible and artefact-free image reconstruction for structural and functional QSM and other phase-critical imaging applications.Magma (New York, N.Y.) · 2026