MORSE-PI: flexible and artefact-free image reconstruction for structural and functional QSM and other phase-critical imaging applications.
Barbara Dymerska, Oliver Josephs, Benjamin James, Vahid Malekian, Nadine N Graedel, Martina F Callaghan
The Functional Imaging Laboratory, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, WC1N 3AR, UK. b.dymerska@ucl.ac.uk. · The Functional Imaging Laboratory, Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, WC1N 3AR, UK.
Key points
From the paper's conclusion- We present a novel image reconstruction method, MORSE-PI, designed to produce high-SNR, artefact-free, and singularity-free phase images for both structural (SWI, QSM) and functional (fQSM) phase-based brain imaging.
Abstract
PURPOSE: Phase imaging applications such as QSM are highly sensitive to noise amplifications, phase singularities, and other artefacts, particularly in challenging scenarios such as ultra-high field (7 T), under-sampled or single-echo acquisitions. We present a novel image reconstruction method, MORSE-PI, designed to produce high-SNR, artefact-free, and singularity-free phase images for both structural (SWI, QSM) and functional (fQSM) phase-based brain imaging. METHODS: MORSE-PI extends our previous approach, MORSE, by introducing a Virtual Reference Coil (VRC). The VRC is constructed as a linear combination of coil sensitivity maps, with correlations enhanced between coil elements using the noise covariance matrix. Such a VRC ensures robust signal support across the entire brain and is used to correct phase offsets in the MORSE-derived coil sensitivity estimates, resulting in artefact-free, high-SNR phase. RESULTS: Compared to GRAPPA with ASPIRE phase correction, MORSE-PI demonstrates greater robustness to artefacts such as noise amplification and aliasing, and shows improved reproducibility in structural imaging at both 3 T and 7 T. Unlike ESPIRiT and GRAPPA combined with adaptive coil combination methods, MORSE-PI yields singularity-free phase maps. MORSE-PI enables high-SNR reconstructions even for the most challenging scenarios, such as single-echo EPI at 7 T. Its efficient, containerised implementation using the Gadgetron framework supports deployment on the MRI scanner console during measurements. CONCLUSION: MORSE-PI offers a flexible and computationally efficient solution for generating high-SNR, artefact- and singularity-free phase images in both single- and multi-echo GRE and EPI acquisitions. This makes it particularly well-suited for structural and functional QSM, as well as other phase-based MRI applications. Its robustness and rapid computational time facilitate efficient deployment on scanners across field strengths.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRIarXiv · 2026
- Phase‐Pole‐Free Images and Smooth Coil Sensitivity Maps by Regularized Nonlinear InversionMagnetic Resonance in Medicine · 2026
- PI-uMSS: Prior information-based unsupervised magnetic source separation in quantitative susceptibility mappingNeuroImage · 2025
- Phase-Constrained Self-Supervised Reconstruction and Denoising for Ultra-High-Resolution MRI.ArXiv · 2026
- Susceptibility source separation via Closed-form Alternating Newton-type OptimizationarXiv · 2026
- Optimising 7T-fMRI for Imaging Regions of Magnetic Susceptibility.Human brain mapping · 2026