arXivPreprintOpen accesseess.IV

LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising

Fatma Elif Yal\c{c}{\i}nda\u{g}, Mehmet Ozan \"Unal, Metin Erta\c{s}, \.Isa Y{\i}ld{\i}r{\i}m

Key points

From the paper's conclusion
  • We propose a local band-weighted noise power spectrum loss (LBW-NPS) that compares spectral energies within overlapping Hann-tapered patches, without tissue-specific loss conditioning.

Abstract

Low-dose CT denoising should suppress noise while retaining the local texture of the reference image. Matching a pooled spectrum can overlook regional discrepancies, whereas pixel losses alone can favor overly smooth outputs. We propose a local band-weighted noise power spectrum loss (LBW-NPS) that compares spectral energies within overlapping Hann-tapered patches, without tissue-specific loss conditioning. Each valid patch contributes a weighted squared log-energy difference across three frequency bands, alongside an $L_1$ reconstruction term. We compare LBW-NPS against $L_1$-only training and five auxiliary-loss baselines using the same U-Net and three seeds on DeepLesion slices with simulated low-dose acquisitions, including patch-scale ablations and lung, soft-tissue, and bone evaluations. On 220 test slices from 31 patients, LBW-NPS reduces a local spectral gap related to the loss, on $64\times64$-pixel evaluation windows, by 31.9% relative to pooled band-weighted NPS, without a statistically significant PSNR change. This improvement is supported by lower errors relative to the reference in average NPS frequency and gray-level co-occurrence matrix (GLCM) measures not used in the loss, evaluated in homogeneous soft tissue. Local band-power matching therefore improves regional texture agreement without changing the denoising architecture.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers