Intracranial pressure waveform estimation using extracranial signals with deep learning
A. Goyal, V. Zaveri, C. W. Harris, R. D. Stevens
Key points
From the paper's conclusion- We tested whether deep learning models trained on routinely acquired extracranial signals can estimate ICP waveforms with clinically motivated point-estimate accuracy.
Abstract
Continuous intracranial pressure (ICP) monitoring requires invasive instrumentation and reaches only a subset of the critically ill patients who may need it. We tested whether deep learning models trained on routinely acquired extracranial signals can estimate ICP waveforms with clinically motivated point-estimate accuracy. Five architectures were trained on arterial blood pressure (ABP), photoplethysmography (PPG), and electrocardiography (ECG) waveforms, using invasive intraparenchymal ICP as ground truth, and compared across two fusion strategies and three training objectives. Models were externally validated on the independent MIMIC-III (Medical Information Mart for Intensive Care III) Waveform Database. Performance was assessed by mean absolute error (MAE) and Pearson correlation (r). Across 158 critically ill adults (~5,322 hours) from two institutions, external MAE of configurations selected using internal validation data only ranged from 4.266 to 5.899 mmHg and r from 0.585 to 0.719; three of five architectures (multiscale encoder-decoder, long-memory recurrent, temporal convolutional) fell below a clinically motivated 5 mmHg benchmark. Unlike prior work validated within single-site cohorts, these models generalized across institutions at the level of mean pressure and pulsatile trend, but did not reproduce beat-level peak morphology. This work extends prior research through large-cohort, cross-institutional validation and motivates evaluation across broader populations and ICP ranges.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk CalibrationarXiv · 2026
- Data for Machine Learning Models: Clinical Experience Determines Interrater Reliability in Waveform Anomaly Detection.Neurocritical care · 2026
- Estimation of Intracranial Elasticity and Venous Outflow Resistance from Arterial Pressure and ICP Waveforms in Severe Brain InjuryNeurocritical Care · 2026
- Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical TranslationarXiv · 2026
- A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical CarearXiv · 2026
- Estimating Short-Term Heart Rate Variability from Ultra-Short PPG: Mitigating Systematic Bias Using Deep Learning.IEEE journal of biomedical and health informatics · 2026