ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT
Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong, Junjie Huang, Tianye Niu, Lequan Yu
Key points
From the paper's conclusion- We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question.
Abstract
Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size ScalingarXiv · 2026
- Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT ReconstructionarXiv · 2026
- Tomographic Sparse View Selection using the View Covariance LossarXiv · 2026
- Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CTarXiv · 2026
- Decision-Native Multimodal Clinical Modeling via Anatomical Grounding and Confidence CalibrationarXiv · 2026
- SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT ReconstructionarXiv · 2026