Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size Scaling

Yitian Tang, Yuncheng Zhang, Hualiang Wang, Zuozhu Liu

Key points

From the paper's conclusion
  • These results distinguish interpolation placement from network architecture and support NK normalisation for step calibration.

Abstract

Dual-domain networks combine projection and image processing for sparse-view low-dose computed tomography (CT). We quantify the contribution of angular interpolation before learning and distinguish its roles in sinogram initialisation and the image residual base. On synthetic parallel-beam data, parameter-free interpolation reduces noise-free missing-view mean absolute error by 99.7% relative to zero filling at 60 views. Full-view filtered back-projection (FBP) of the jointly learned completed sinogram adds 1.27 dB of peak signal-to-noise ratio (PSNR) over interpolated FBP. In a data-consistency dual-domain network (DC-DuNet), a 2x2 configuration ablation controls branch width, depth and training schedule while varying these placements and their associated input channels. After 20 epochs, the PSNR contrasts are +1.98 dB for sinogram initialisation and -2.16 dB for the interpolated image base; the image-base ranking also reverses during training. The sinogram-initialised variant exceeds an image-only U-Net by 0.96 dB at 60 views and 10% dose, and by 1.28 dB on independently generated synthetic data. The U-Net leads at higher view counts and with a shared interpolated image base. Without retraining, the variant retains a 0.12 dB advantage on held-out CHAOS abdominal CT under simulated degradation; the image-base contrast rounds to zero. The implemented projection/backprojection pair has empirical dominant gain of approximately 0.85NK, where N is image-grid width and K acquired view count. These results distinguish interpolation placement from network architecture and support NK normalisation for step calibration.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size Scaling — Science Skim