Continuous Lower-Limb Joint-Angle Estimation from sEMG and IMU: The Conditional Value of Cross-Activity and Cross-Subject Data under Update-Matched Controls
Jiaying Xu (Conamur), Guangyuan Chen (Institute of Neuroscience, Chinese Academy of Sciences), Buyun Gao (Conamur), Zhen Dong (University of California, Santa Barbara)
Key points
From the paper's conclusion- We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset.
Abstract
Intent-driven exoskeleton control needs a continuous, causal estimate of the wearer's joint kinematics and an answer to a second question: whose data should train the estimator for a new user? Borrowing the user's recordings of other activities, or other users' recordings of the same activity, is usually evaluated as "more data" versus "less data," which confounds the information a source carries with the optimizer updates it adds and hides negative transfer behind averages. We separate these effects for hip, knee, and ankle angle estimation from high-density sEMG and an IMU across six locomotion activities on all ten participants of a public dataset. A compact residual causal TCN-GRU decoder is frozen, and an update-matched replay control prices every added source against the same number of updates on the user's own data. A user's own other activities raise $R^2$ from 0.722 to 0.788, of which +0.048 is information beyond replay; stair descent is a reliably harmful donor and sit-stand-walk a reliably beneficial one. Other users' same-activity data help while the user has only the target activity ($G_\mathrm{T} = +0.053$) and half as much once own other-activity data exist ($G_\mathrm{W} = +0.028$); at full calibration, donor value collapses after one to two target records. Per-target gains from the two sources correlate, and leave-one-participant-out gates recover most of the cross-subject value only at low calibration. Data value is hierarchical, state-dependent, and directional; the bottleneck is deciding, without test labels, when to transfer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Effective Semi-Subject-Independent sEMG-Based Learning Framework to Continuously Predict Knee Joint Trajectory.IEEE transactions on cybernetics · 2026
- A Unified Kinematic Representation Enables Reusable Biological Joint Moment EstimationarXiv · 2026
- sEMG-IMU Fusion with Transfer Learning for Knee Flexion and Adduction Moment Estimation During Tai Chi.Sensors (Basel, Switzerland) · 2026
- Deep learning for motion classification in ankle exoskeletons using surface EMG and IMU signalsScientific Reports · 2025
- Multi-joint and multi-planar lower-limb moment prediction from four inertial measurement units with target-subject adaptation.Frontiers in bioengineering and biotechnology · 2026
- Learning Ankle Exoskeleton Control for Reactive Standing Balance Through Neuromusculoskeletal SimulationarXiv · 2026