Frontiers in bioengineering and biotechnology

Multi-joint and multi-planar lower-limb moment prediction from four inertial measurement units with target-subject adaptation.

Xinyu Fan, Tao Ma, Ningbo Yu, Jianda Han, Jiayin Guan, Monan Ni, Tao Sun

Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education and Institute for Embodied Intelligence, Tianjin University, Tianjin, China. · College of Artificial Intelligence, Nankai University, Tianjin, China.

Key points

From the paper's conclusion
  • We evaluated the model on 14 participants performing level walking, stair ascent, and stair descent under nested subject‐level leave‐one‐subject‐out cross‐validation.

Abstract

INTRODUCTION: Accurate and continuous prediction of multi-planar lower-limb joint moments is crucial for clinical rehabilitation, sports science, and assistive device design. However, gold-standard methods rely on bulky, expensive laboratory-bound equipment, and existing wearable solutions are often limited to single-joint or single-plane predictions, or require dense sensor arrays impractical for daily living. METHODS: To address these limitations, we propose an end-to-end multi-task temporal convolutional network framework. Using only four inertial measurement units sparsely placed on the pelvis and lower limb, the framework simultaneously predicts five continuous joint moments: hip and knee moments in the coronal plane, and hip, knee, and ankle moments in the sagittal plane. A hard-parameter-sharing temporal convolutional backbone extracts cross-joint temporal features, while point-wise channel attention enables task-specific feature reweighting. Adaptive batch normalization (AdaBN) further enables target-subject adaptation using a 10-s segment of unlabeled level-walking data. We evaluated the model on 14 participants performing level walking, stair ascent, and stair descent under nested subject-level leave-one-subject-out cross-validation. RESULTS: The proposed model achieved the highest numerical overall R2 among models evaluated without target-subject adaptation and significantly outperformed four of the six external baselines; AdaBN further improved the overall R2 to 0.759 ± 0.032. Ablation experiments showed that hard parameter sharing, point-wise channel attention, and AdaBN increased the overall R2 by ΔR2 = 0.017, 0.026, and 0.032, respectively (all Holm-adjusted p < 0.05). Supplementary evaluation on an independent public dataset yielded R2 values of 0.704-0.840 across four joint-moment targets. DISCUSSION: These findings demonstrate the feasibility of continuous multi-joint and multi-planar moment prediction using a sparse wearable sensor configuration under controlled laboratory conditions and support further evaluation in larger and clinically diverse cohorts and in out-of-laboratory settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers