arXivPreprintOpen accesseess.SY

Power Management of Electrically Driven Centrifugal Compressors for Flexible Operation

Alp Albay, Tak Lam Fok, Niklaus Hung, Maiken Omtveit, Mehmet Mercang\"oz

Key points

From the paper's conclusion
  • We present a control strategy for power management of a variable-speed 15MW (rated power) centrifugal compressor, and investigate how quickly it can follow a reduced electrical power reference without entering surge.

Abstract

We present a control strategy for power management of a variable-speed 15MW (rated power) centrifugal compressor, and investigate how quickly it can follow a reduced electrical power reference without entering surge. We use a Greitzer-Gravdahl type model scaled to industrial size with rate-limited valve actuators as a simulation environment and propose an advanced regulatory control structure using feedback control loops with dynamically scaled feedforward mechanisms and a structure of min/max selectors. In simulated experiments, a 6MW power reduction from varying initial operating points on a 12MW iso-power line is delivered at rates of up to 10MW/s, i.e.to 90% in 0.54s, without opening the recycle valve. Depending on the initial operating point, a large power reduction can be delivered at once or with a restricted ramp rate. The stroking rate of the discharge side valve is identified as the limiting factor for how fast the power can be reduced in the studied configuration. A limited sensitivity study on the impact of rotor inertia for power shedding performance is also provided.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers