Retrofitting centralized air compressor stations with end-use-aware predictive set-pressure control using a physics-constrained pressure-drop model
Taito Watanabe, Yohei Kono, Akira Iyozumi, Takashi Nakajima
Key points
From the paper's conclusion- A lightweight hierarchical nonlinear model predictive control (NMPC) scheme, retrofitted to the sequencing controller of a centralized compressor station typical of small and medium-sized plants, lowers the set pressure as far as the end-use requirement allows.
Abstract
Compressed air systems usually run at a constant set pressure well above the end-use requirement; the excess margin is wasted energy. A lightweight hierarchical nonlinear model predictive control (NMPC) scheme, retrofitted to the sequencing controller of a centralized compressor station typical of small and medium-sized plants, lowers the set pressure as far as the end-use requirement allows. It uses only two pressure gauges (receiver and one critical end-use point) and compressor data, without flow meters or piping surveys. The end-use pressure is predicted by a low-order pressure-drop model identified by least squares under stability, damping and steady-state equilibrium constraints, which serve use rather than accuracy: they let the measured pressure drop be held over the horizon with unit gain. Validated in three stages (plant data, a pipe-network simulator checked against measurements, and the actual controller, at most 1.41 s per update), the NMPC meets the required pressure under real demand and reduces the estimated annual energy consumption by 2.8 % relative to the current constant operation (9.3 % relative to 0.70 MPa). A PID cascade with the same gauge saves about as much only when tuned by a standard rule at its recommended setting from a constant-load step test, difficult in an operating plant; the NMPC needs no such test and keeps its performance with its initial model and default weights after plant expansion and network split. The margin becomes a design parameter instead of a fixed excess, and the controller's signals show where the supply system lacks headroom.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Online Optimization for Controlling HVAC SystemsarXiv · 2026
- Convex, Real-Time Koopman Model Predictive Control of Activated-Sludge Aeration: Constraint-Aware Operation With an Explicit Energy-Nitrous-Oxide Operating Frontier.Water environment research : a research publication of the Water Environment Federation · 2026
- Operating-envelope assessment of static-pressure reset control in VAV systemsE3S Web of Conferences · 2026
- Optimal Control of Dynamic Gas Networks Using Gaussian Processes with Chance-Constraint ReformulationarXiv · 2026
- Experimental Comparison of Control Strategies for Heat Recovery from Compressors Under Variable Operating ConditionsEnergies · 2026
- A self-contained model-based predictive control framework for HVAC systems using sequential proactive system identificationEnergy and Buildings · 2026