Accurate calibration method of the Back-linked Fabry Perot interferometer using null channel for space-based gravitational wave antenna
Yusuke Okuma, Shoki Iwaguchi, Ryosuke Sugimoto, Yutaro Enomoto, Kiwamu Izumi
Key points
From the paper's conclusion- Therefore we can estimate the cavity response by optimizing the response parameters to minimize the integrated power of the null channel.
Abstract
Accurate calibration of the detector response is essential for precision gravitational-wave (GW) observations. In the Back-linked Fabry-Perot Interferometer (BLFPI), which employs Fabry-Perot cavities to achieve high GW sensitivity, accurate calibration of the cavity response is particularly important because residual calibration errors directly limit the suppression of laser frequency noise. However, no practical calibration strategy for the cavity response has yet been established. In this paper, we propose a method for calibrating the cavity response using a null channel constructed from the three interferometer outputs of the triangular laser-link configuration. In null channel, GW signals are canceled and residual laser frequency noise indicates errors in the cavity response estimates. Therefore we can estimate the cavity response by optimizing the response parameters to minimize the integrated power of the null channel. We derive the estimation bias introduced by technical noise analytically and evaluate the performance of the proposed method numerically. The results show that the residual laser frequency noise after calibration is more than an order of magnitude below the designed BLFPI sensitivity throughout the observation band. This demonstrates that the proposed null-channel calibration method achieves the accuracy required for effective subtraction of laser frequency noise.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal-dither wavefront sensing: Calibration-free measurement of mode mismatcharXiv · 2026
- Characterization of integrating-sphere systematic effects for photon calibration of the KAGRA gravitational wave detectorarXiv · 2026
- Recent Development of the Laser Interferometer for Taiji Space Gravitational Wave DetectionResearch · 2026
- Model bias and calibration uncertainty in dispersive interrogation of fiber-optic Fabry–Perot sensorsMeasurement Science and Technology · 2026
- Improved accuracy of the reference photon calibration standards in the network of gravitational-wave observatories during the O4 observing runarXiv · 2026
- Estimation of systematic error from bulk deformation of end test mass induced by photon calibrator for LIGO post-O5 gravitational wave projectsClassical and Quantum Gravity · 2026