EQUIP-RPT: A framework for objective evaluation of quantitative imaging methods in radiopharmaceutical therapies
Zekun Li, Carlos F. Uribe, Fereshteh Yousefirizi, Lidia Strigari, Neeta Pandit-Taskar, Jazmin Schwartz, Julia Brosch-Lenz, Babak Saboury,
Key points
From the paper's conclusion- We outline the EQUIP-RPT framework based on image-science and task-based image-quality evaluation methodology, practical considerations, and recent literature.
Abstract
Quantitative imaging (QI) provides a non-invasive approach for dosimetry and quantitative response assessment in radiopharmaceutical therapies (RPTs). QI methods are being developed for instrumentation, acquisition, reconstruction, and image analysis. However, a key barrier to routine adoption of these methods is that evidence demonstrating reliable performance of QI methods on clinically relevant quantification tasks in RPTs remains limited. Our goal is to outline the Evaluation of Quantitative Imaging Performance in Radiopharmaceutical Therapy (EQUIP-RPT) framework, a structured approach for objective, task-based evaluation of QI methods for RPTs. We outline the EQUIP-RPT framework based on image-science and task-based image-quality evaluation methodology, practical considerations, and recent literature. The framework is organized around four linked design steps: (i) specification of the quantification task, (ii) design of the study population and imaging protocol, (iii) task-specific information extraction, and (iv) selection of figures of merit (FoMs). The EQUIP-RPT framework is presented in the context of four quantification tasks in RPT: activity uptake, absorbed dose, volumetric tumor burden, and lesion-level longitudinal quantifications. The framework distinguishes two paradigms for task-specific information extraction and organizes FoMs according to the performance attributes they characterize. We describe key elements to apply the EQUIP-RPT framework in simulation, physical phantom, and clinical studies. Finally, we show how EQUIP-RPT can be used to generate a quantitative claim based on the evaluation study. The EQUIP-RPT framework is designed to provide a structured approach for objective task-based evaluation of QI methods in RPTs, thereby facilitating clinical translation of these methods.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Towards practical radiopharmaceutical treatment planning: a review of dosimetry simplification techniques.Theranostics · 2026
- Quantitative Comparison of SPECT and PET Performance for Clinical Theranostic ApplicationsJournal of Nuclear Medicine · 2025
- Dosimetry Data Infrastructure for Individualized Radiopharmaceutical Therapy: International Experience and a Proposed Framework for China.Pharmaceuticals (Basel, Switzerland) · 2026
- Artificial intelligence across oncologic theranostics: evidence for patient stratification, dosimetry, and adaptive radiopharmaceutical therapy.Frontiers in nuclear medicine · 2026
- Energy deposition and receptor saturation set a tumour size threshold for radiopharmaceutical therapy: insights from a pharmacokinetic-tumour dynamics modelbioRxiv · 2026
- An International Study of Factors Affecting Variability of Dosimetry Calculations, Part 6: Lessons Learned, Achievable Variability, and the Road Ahead.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026