Artificial intelligence across oncologic theranostics: evidence for patient stratification, dosimetry, and adaptive radiopharmaceutical therapy.
Mallareddy Banala, Shabbir Ezuddin, Mark Foley, Russ Kuker
Department of Radiology, University of Miami Miller School of Medicine and Jackson Health System, Miami, FL, United States.
Key points
From the paper's conclusion- We conducted a structured narrative review with descriptive mapping of learned models for patient stratification, segmentation, tumor-burden quantification, quantitative preprocessing, dosimetry, toxicity prediction, response assessment, and radiation-safety/logistics support.
Abstract
Artificial intelligence (AI) has been studied across radiopharmaceutical therapy (RPT); however, evidence for treatment-changing use remains limited. We conducted a structured narrative review with descriptive mapping of learned models for patient stratification, segmentation, tumor-burden quantification, quantitative preprocessing, dosimetry, toxicity prediction, response assessment, and radiation-safety/logistics support. The mapped set contained 73 direct full journal reports and eight direct conference abstracts, with one additional meeting abstract retained as contextual evidence. Among the full reports, 17 were PSMA-related, 16 SSTR/PRRT, 15 radioiodine, 14 ⁹⁰Y radioembolization, and 11 cross-platform or emerging-target reports; 16 addressed segmentation or quantification, 32 selection, response, prognosis, toxicity, or safety/logistics, and 25 registration, preprocessing, or dosimetry. Fifty-one reports were retrospective, one was an explicitly prospective clinical/technical evaluation, nine were technical, synthetic, or phantom evaluations, and temporal design was unclear or conflicting in 12. Seven reported an external-type held-out evaluation, including four that clearly held out an institution; one reported explicit calibration, one propagated task-level uncertainty, and none evaluated a prospective AI-guided treatment policy. The mapped evidence most directly supports human-reviewed measurement and workflow assistance. An eight-domain RPT evidence-to-decision synthesis organizes quantitative fidelity, reference standards, validation, endpoints, biological linkage, oversight, uncertainty and quality assurance, and decision impact; it is not a validated score or adoption standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial Intelligence Across the Cancer Theranostics Workflow: Critical Appraisal of Current Evidence and Future Clinical Translation.Molecular imaging and biology · 2026
- Towards practical radiopharmaceutical treatment planning: a review of dosimetry simplification techniques.Theranostics · 2026
- AI-driven radiopharmaceutical dosimetry optimization for theranostics: a systematic review and meta-analysis.Revista espanola de medicina nuclear e imagen molecular · 2026
- Personalised Dosimetry in Nuclear Medicine: Bridging Physics, Biology and AI for Next Generation Radiopharmaceutical Therapy.Nuclear medicine and molecular imaging · 2026
- Artificial intelligence in personalized internal dosimetry for radiopharmaceutical therapy: a narrative mini-review.Nuclear medicine communications · 2026
- From Patient Selection to Surveillance: Artificial Intelligence Applications in Radioiodine Therapy - A Systematic Review.Nuclear medicine and molecular imaging · 2026