Rapid Antigen Detection Tests Empowered by Cholesteric Spherical Reflectors for Expanded Capabilities
Chih-Chieh Chien, Yan-Song Zhang, Jean-Fran\c{c}ois Conrotte, Carole L. Linster, Sivashankar Krishnamoorthy, Jan P. F. Lagerwall
Key points
From the paper's conclusion- We explore the potential of Cholesteric Spherical Reflectors (CSRs) as enhanced optical labeling probes for RADTs, leveraging their circularly polarized reflections to maximize contrast by background subtraction and thereby lower the analyte concentration required for detection.
Abstract
While Rapid Antigen Detection Tests (RADTs) have proved their value in point-of-care detection of respiratory diseases, their poor-contrast readout limits their use at early stages of infection where viral concentrations are low, and most RADTs test only for one disease, leaving a sick patient ignorant in case of a negative result. We explore the potential of Cholesteric Spherical Reflectors (CSRs) as enhanced optical labeling probes for RADTs, leveraging their circularly polarized reflections to maximize contrast by background subtraction and thereby lower the analyte concentration required for detection. Moreover, we demonstrate how the ease in tuning the CSR reflection color and the freedom to choose between right- and left-handed circularly polarized reflection allow us to design CSRs to distinguish optically between multiple diseases, eventually enabling RADTs capable of screening for a set of multiple diseases in a single test. We develop a method for functionalizing CSRs with appropriate antibodies and we propose a new type of RADT specifically designed for use with CSRs as detection label, demonstrating that the comparatively large size of CSRs (tens of microns in diameter) does not prevent viral analytes to tether them to an antibody-coated test surface. The strength of the optical CSR signal quantitatively reflects the antigen concentration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- SERS-Active Nanocomposite Contact Lenses for Label-Free Multiplexed Biosensing of Tear Analytes.ACS applied materials & interfaces · 2026
- Virus gene sensing detection method based on TiO2NR @ AgNPs chip and the multifunctional SERS microspheresApplied Surface Science Advances · 2026
- Dual-Format Plasmonic Biosensors for the Detection of SARS-CoV-2 and the Oxidative Stress Biomarker sNOX2-dpACS Applied Nano Materials · 2026
- Multimodal LFIA platform integrating visual readout, smartphone grayscale imaging and surface-enhanced Raman scattering for point-of-care detection of SARS-CoV-2 protein.Analytical methods : advancing methods and applications · 2026
- A New Ratiometric SERS Sensing Strategy Based on Molecular Dissociation Using Dual-Alkyne Reporters.Analytical chemistry · 2026
- Plasmonic SPR sensor using SiO₂ /Ag-Au alloy/Cu/LaF/Graphene novel Kretschmann structure for SARS-CoV-2 detection: A theoretical studyModern Physics Letters B · 2026