Safeguarding Agentic AI in Radiology Workflows: A Multimodel Evaluation of Rule-based and Large Language Model-based Verification
Semil Eminovic, Robin Schmidt, Bogdan Levita, Maximilian Lindholz, Tobias Penzkofer, Jawed Nawabi
Key points
From the paper's conclusion- Most blocked actions (64%-68%) would not have caused a violation and were returned for revision.
Abstract
Purpose: To estimate how often tool-using large language model (LLM) agents record clinically relevant false or unsupported information in simulated radiology documentation and how much safeguards applied before each action reduce these errors. Materials and Methods: In this simulation study (October 2026), 48 synthetic, radiologist-reviewed base scenarios covered finding communication, tumor board preparation and follow-up management. Forty-three also had a misleading-information variant (91 variants). Six LLM agents (Claude Sonnet 5.5, GPT-6.1-Sol, GLM-5.3, MiniMax M3, Gemma-4-31B, Qwen3.8-27B) completed each variant with permissions only, deterministic rules, and rules plus a locally run LLM checker (1638 episodes). The primary outcome was at least one executed high-severity violation per episode. Risk differences were estimated per agent at base-scenario level and, exploratorily, pooled across agents, with analyses of document access and blocks. Results: With permissions only, 7.3%-27.1% of episodes had a high-severity violation (pooled across agents, 19.4%). Pooled, it was 16.7% with rules (-2.8 percentage points; 95% CI: -6.1, 0.5) and 13.2% with rules plus the LLM checker (-6.2; 95% CI: -9.5, -3.0). Adding the LLM checker to rules changed it by -3.5 (95% CI: -6.3, -0.7). No difference between agents was detected (P = .43), and task success did not decrease detectably. In misleading variants, agents opened the altered document in 83% of episodes regardless of error, and 58% of erroneous statements cited it. Most blocked actions (64%-68%) would not have caused a violation and were returned for revision. Conclusion: Layered safeguards reduced but did not prevent high-severity errors. Errors after misleading information reflected misjudged rather than missed information.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agentic AI Systems in Radiology: Design, Applications, Evaluation, and Challenges.Radiology · 2026
- RADAR: A Prototype for Grounding Large Language Model Consult Support in an ACR-Structured Appropriateness Knowledge Base with Citation Validation and Abstention.Journal of imaging informatics in medicine · 2026
- Guardrail-Based Radiology Protocolling with Large Language Models: Balancing Automation and Oversight.Journal of imaging informatics in medicine · 2026
- A medically grounded LLM agent-based tool to detect patient safety events in medical records.PLOS digital health · 2026
- Verifiable Logic in Medical LLMs: A Critical Review of Agentic Clinical Reasoning Optimization and Neuro-Symbolic GroundingarXiv · 2026
- Agentic artificial intelligence in radiology workflow: from image interpretation to report quality control.Frontiers in medicine · 2026