Guardrail-Based Radiology Protocolling with Large Language Models: Balancing Automation and Oversight.
Alexander W Marka, Caroline Reinhold, David Nassim, Daniela Pfeiffer, Jean-Pierre Pelage, Khashayar Namdar, Dominik Deniffel
Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich (TUM), Munich, Germany. · Department of Radiology, McGill University Health Centre, Montreal, QC, Canada.
Key points
From the paper's conclusion- A guardrail-first LLM protocolling workflow combined high-performance automation with reliable identification of requests requiring radiologist review, supporting further prospective evaluation.
Abstract
Safe clinical deployment of large language models (LLMs) for radiology protocolling requires knowing when not to automate. We evaluated a "guardrail-first" workflow that defers incomplete or safety-critical CT and MRI requests to radiologists before assignment. In this single-center retrospective study, 537 body imaging requests were temporally split into prompt development (n = 109) and validation (n = 428) cohorts. An expert radiologist classified requests as protocol-eligible or requiring review. Six LLM pipelines (Gemini 3.1 Pro, Claude Sonnet 4.6, GPT-5.2, GPT-5.2 high, DeepSeek V3.2, and DeepSeek V3.2 reasoner) were evaluated in two stages (review triage, protocol assignment) against human protocolers. Primary outcome was clinically appropriate assignment (exact/equivalent protocol or correct review escalation), with bootstrapped 95% CIs. The expert reference standard classified 57/428 requests (13.3%) as requiring review (15 safety-critical, 23 major missing information, 19 minor clarification). For the 38 requests with safety-critical issues or major missing information, Gemini 3.1 Pro achieved 100% sensitivity (38/38; 95% CI, 90.7-100), versus 94.7%-97.4% for other pipelines. Among 371 protocol-eligible requests, unnecessary escalation ranged from 1.3% (5/371) to 34.0% (126/371), remaining lowest for reasoning-enabled models. The human benchmark achieved 83.6% (95% CI, 79.8-87.3) exact/equivalent assignment, exceeded by Gemini 3.1 Pro (+12.7 percentage points; 95% CI, 8.6-16.7), Claude Sonnet 4.6 (+12.4; 8.4-16.4), GPT-5.2 high (+11.6; 7.3-15.9), and DeepSeek V3.2 reasoner (+8.6; 4.3-12.9). End-to-end clinically appropriate assignment ranged from 65.0% (60.5-69.4) for GPT-5.2 to 96.3% (94.4-97.9) for Gemini 3.1 Pro; the three highest-performing pipelines did not differ significantly. A guardrail-first LLM protocolling workflow combined high-performance automation with reliable identification of requests requiring radiologist review, supporting further prospective evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy and reliability of privacy-compliant large language models for MRI protocol selection in radiological workflows.European radiology · 2026
- Large language models in radiology workflows: OpenEvidence dotflows as an accessible, evidence-centered resource.Current problems in diagnostic radiology · 2026
- RADAR: A Prototype for Grounding Large Language Model Consult Support in an ACR-Structured Appropriateness Knowledge Base with Citation Validation and Abstention.Journal of imaging informatics in medicine · 2026
- Safeguarding Agentic AI in Radiology Workflows: A Multimodel Evaluation of Rule-based and Large Language Model-based VerificationarXiv · 2026
- Large Language Models in the Radiology Workflow: Current Applications, Challenges, and Future Perspectives.Journal of the Korean Society of Radiology · 2026
- Effectiveness, Safety, and Workflow Burden of Large Language Model-Based Medical Report Generation: Systematic Review.Journal of medical Internet research · 2026