Comparative laboratory analysis of window sound insulation across glazing types in the 50–5000 Hz range: evaluation of different low-frequency methods
David Caballol Bartolome, M. De Los Angeles Navacerrada Saturio, Daniel De La Prida Caballero, Alexander Díaz Chyla, Antonio Pedrero González
Universidad Politécnica de Madrid
Key points
From the paper's conclusion- This study investigates the sound insulation performance of windows by presenting laboratory measurements from 50 to 5000 Hz on two window types, with and without an integrated shutter box, each tested across five glazing configurations.
Abstract
This study investigates the sound insulation performance of windows by presenting laboratory measurements from 50 to 5000 Hz on two window types, with and without an integrated shutter box, each tested across five glazing configurations. While all measurements were conducted under controlled laboratory conditions, particular attention was given to the low-frequency range (50–100 Hz), where every measurement method available in the standard was applied. These included procedures based on the laboratory standard (ISO 10,140), the in situ standard (ISO 16,283), and a hybrid approach, all implemented within the laboratory setting. The results reveal that below 100 Hz, sound insulation values and differences between window types vary significantly depending on the measurement method. The in situ procedure, when applied only to the receiving room—as is common in façade assessments—yields the lowest insulation values and minimizes differentiation between window types, likely due to room modal effects. In contrast, applying the same procedure to both the source and receiving rooms produces results that more closely align with those obtained using laboratory standards. Furthermore, while the window without a shutter box generally provided higher insulation above 100 Hz, it exhibited a more pronounced reduction in insulation below 100 Hz under laboratory conditions, highlighting a potential source of low-frequency discomfort not reflected in standard manufacturer ratings. These findings underscore that low-frequency sound insulation ratings are highly dependent on the measurement approach, emphasizing the need to refine standardized protocols and enhance the reliability and perceptual relevance of acoustic descriptors in this frequency range.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability of Microphone-Based Experimental Modal Analysis of Beech Wood Cantilevers with Flexible Adhesive Bond-Lines.Materials (Basel, Switzerland) · 2026
- Study on reliability and error of in situ measurements for liner impedance under grazing flowJournal of Physics: Conference Series · 2026
- In Situ Acoustic Assessment of a Timber-Frame Floor: Airborne and Impact Sound Insulation Under ISO 717Buildings · 2026
- Field-relevant metrological performance of water meters: a topical review for water-infrastructure monitoringMeasurement Science and Technology · 2026
- Analysis of Variability in Heavy-weight Floor Impact Sound Insulation in Multi-residential Buildings with Identical Floor StructuresTransactions of the Korean Society for Noise and Vibration Engineering · 2026
- Comparative Analysis of Thermal Bridges and Condensation Risk Based on Installation Positions of Single- and Double-Window Systems in Externally and Internally Insulated Concrete WallsBuildings · 2026