In Situ Acoustic Assessment of a Timber-Frame Floor: Airborne and Impact Sound Insulation Under ISO 717
Marko Kršulja, Elvis Ciliga, Lovro Liverić, Damir Karabaić
Key points
From the paper's conclusion- The paper therefore distinguishes measured apparent sound insulation, source-spectrum context, receiving-room response, and analytical sensitivity without presenting the scenario calculations as validated acoustic optimization.
Abstract
Single-number ratings are widely used in building acoustics, but they are meaningful only when the reference-curve procedure is applied correctly and the reported descriptors are matched to the physical problem. This study re-evaluates accredited in situ measurements of airborne and impact sound insulation for a timber-frame interfloor construction at the Archaeological Museum of Istria, Croatia. Applying the measured one-third-octave spectra in 1 dB reference-curve steps according to ISO 717 gives R′w = 55 dB and L′n,w = 62 dB. Both values satisfy the historical Croatian requirements that applied at the time of measurement. For the meeting-room source context, the ISO 717-1 adaptation term C = −3 dB gives R′w + C = 52 dB; Ctr is not used in the internal-partition analysis because it represents a low-frequency-rich, traffic-oriented source spectrum. The impact receiving-room volume is 95.4 m3. A separate diffuse-field scenario estimates how certified broadband absorption would change the unnormalized receiving-room level Li(f); it is not treated as a change in L′n,w, and no band-by-band 60 dB compliance threshold is applied. A separate sensitivity analysis of floating-floor resonance gives f0 = 28–89 Hz over the selected mass–stiffness range, with an as-built estimate of about 53 Hz. The paper therefore distinguishes measured apparent sound insulation, source-spectrum context, receiving-room response, and analytical sensitivity without presenting the scenario calculations as validated acoustic optimization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analysis of Variability in Heavy-weight Floor Impact Sound Insulation in Multi-residential Buildings with Identical Floor StructuresTransactions of the Korean Society for Noise and Vibration Engineering · 2026
- Culturally inspired acoustic retrofit for high-density pilgrimage corridors: a pilot physical model study and reproducibility-oriented validation protocolFrontiers in Built Environment · 2026
- A Study of the Sound and Thermal Insulation of Wood Façade Assemblies by Considering Environmental Impact AspectsAcoustics · 2026
- Detection of Active Wood-Boring Insect Larvae Using Acoustic Emission Measurements: Principles, Experimental Validation, and Practical Applications.Sensors (Basel, Switzerland) · 2026
- A Model for Calculating Reverberation Time, Speech Clarity and Sound Strength in Ordinary RoomsAcoustics · 2026
- Nocturnal Sound Architecture for the Malioboro Heritage Corridor: An ISO-based Environmental and Adaptive-lighting Retrofit FrameworkE3S Web of Conferences · 2026