arXivPreprintOpen accesscs.RO

When to Trust the BIM: Identifiability-Aware LiDAR-Inertial--BIM Fusion under As-Built Deviations

Yujie Zhang, Yuxuan Guo, Xinbao Sun, Chunlei Zhao, Langqi Miao, Xiaohui Jia, Jinyue Liu

Key points

From the paper's conclusion
  • In paired fault injections in a laboratory room with its IFC model and on three floors of the SLABIM dataset, it raised no off-target attribution (0 of 168 conditions in the laboratory; 0 of 1,302 on SLABIM) and attributed all eight laboratory faults predicted to be attributable, whereas both reproduced baselines raised off-target structural flags in every setting.

Abstract

Building information models (BIM) can provide a global geometric reference for robot localization with LiDAR-inertial odometry (LIO). However, as-built deviations from the as-designed model mean that a disagreement between a scan and the BIM may arise from a pose error, an offset wall surface (an as-built deviation or an unmodeled object in front of the wall), or a shifted room, and in some geometries these explanations produce identical observations. In this paper, we formalize this attribution problem as fault identification over three fault classes and derive a geometric criterion for when attribution is possible. Building on it, we propose an identifiability-aware method that reports an attribution only when the fault is attributable; otherwise, it retains the candidates, defers BIM updates and BIM-based pose corrections in the ambiguous directions, and recovers once new references arrive. In the pre-registered two-dimensional study, on cases whose fault is detectable but not attributable, the method's conditional error rate was 0.83%, against 31.67% for a baseline with uncertainty-based abstention at the same answer rate. On the 5,600 attributable cases, the method reported a unique attribution 5,574 times, with no incorrect attributions. In paired fault injections in a laboratory room with its IFC model and on three floors of the SLABIM dataset, it raised no off-target attribution (0 of 168 conditions in the laboratory; 0 of 1,302 on SLABIM) and attributed all eight laboratory faults predicted to be attributable, whereas both reproduced baselines raised off-target structural flags in every setting.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

When to Trust the BIM: Identifiability-Aware LiDAR-Inertial--BIM Fusion under As-Built Deviations — Science Skim